16 / 34
S1038_Q06_V1.0pn_en
Note
The height set in the value field of the "Maximum height" line
always refers to the height above the location when the receiver
system is switched on. Actively used, this feature supports the com-
pliance with the various regulations regarding the maximum alti-
tude above ground.
PERIOD
If your system is used exclusively with digital servos, you can set a
cycle time (frame rate) of 10 ms. If using mixed or with the exclusive
use of analogue servos, it is essential to select 20 ms. Otherwise,
analog servos will respond with "trembling" or "growling", even total
failure.
SUMD at channel X
SUMD
S1034 Falcon 12 plus
C5
S1035 Falcon 12
C5
• "No"
The receiver-specific connection is suitable for operating a servo
or comparable RC components.
• "Yes"
If the value field of this line has been set to "yes" and the relevant
receiver is subsequently put into operation again, it permanently
generates a digital sum signal from the control signals of its con-
trol channels and makes this available at the receiver-specific
fixed servo connection. This type of signal was being used by
some of the newest flybarless systems and power supplies.
C5
Servo/Sensor/Voltage
S1035 Falcon 12
C5
S1034 Falcon 12 plus (with vario)
C5
An SBUS signal on C5 is automatically detected at power up so that
the receiver can be operated directly with a receiver using SBUS
instead of HoTT. In this mode, only the SBUS signal is processed,
there is no redundant operation.
• SERVO
The receiver-specific connection is suitable for operating a servo
or comparable RC components.
• SENSOR
The receiver-specific connection is suitable for connecting telem-
etry sensors. When the receiver is switched on, previously con-
nected devices are automatically detected.