12. BATTERY SELECT MENU SCREEN
12. BATTERY SELECT MENU SCREEN
12-1. Balancing cable connection
- If balancing cable is not connected to the balancing port of the charger for
LiIo/LiPo/LiFe, user should set battery cell number.
If wrong cell number is set to the charger, battery could be damaged.
The present voltage is shown as “OUTPUT [ 0.000V ]”
The charger should beep every 3 seconds to indicate you should set cells.
- When balancing cable is connected to the balancing port of the charger,
The charger shows the connected cell number and user needs to recheck if
the correct cell number is shown on the screen.
If cell number shown on the screen is not correct, press the ESC button and
recheck battery cell number or selected cell number.
If selected cell number and connected cell number is not matched,
“CONNECTION ERROR” display should be shown on the screen.
- If cell number is manually set without connecting the balancing cable to the
balancing port of the charger, warn message should be shown on the
screen.
With connected balancer
connector in LiPo/LiIo/LiFe
CC/CV- or automatic mode
Wit connected balancer
connectors in LiPo/LiIo/LiFe
CV-LINK-Mode .
*CONNECTED CHECK* 5
[0] cells at OUT1 &
[0] cells at OUT2
are now connected
at each balancing
port.....Right ?
OUTPUT1 [ _0.000V ]
OUTPUT2 [ _0.000V ]
Balancer connector not connected in
LiPo/LiIo/LiFe-Mode
** BALANCER **
** CONNECTION **
** ADVISED! **
*SELECT CELLS*
Select [0] cells
to be charged or
discharged.
OUTPUT [ _0.000V ]
*CONNECTED CHECK* 5
[0] cells are now
Connected at the
Balancing port
.......Right?
OUTPUT [ _0.000V ]