20
UCP
-
3901 Card Installation and Operation
Front Card-edge Interface
Item
Description
Ident Button
Push to:
• Make the card’s SDI IN LEDs flash.
• Activate the
Configuration
>
Location
>
Where Am I
checkbox in
RollCall.
This works bi-directionally between the card and the RollCall setting.
See also
, on page 48 for more information about the
Where Am I
checkbox.
Ejector Tab
Lift the bottom edge of the ejector tab to lever and remove the card
out of the frame. See
Installation of the Rear Connector Panel and
SDI IN 1 to SDI IN
16 status LEDs
As an input, this shows the following port status:
•
Green:
Signal is detected.
•
Yellow:
Test pattern generator has been activated.
•
Red:
Signal loss.
• Off: Input/Spigot not in use.
As an output, this shows the following port status:
•
Green:
Valid flow is detected.
•
Yellow:
Test pattern generator has been activated.
•
Red:
Flow is not found or invalid.
• Off: Output/Spigot not in use.
See also
, on page 80 and
for more information.
SFP 1 to SFP 4
status LEDs
Shows the SFP 1, 2, 3, and 4 link status:
•
Blue:
Link OK (25G/50G/100G SFP).
•
Blue flashing:
SFP detected, link down (fiber not connected,
different FEC selection from host).
•
Unlit:
SFP not detected.
See also
, on page 62 and
on page 96 for more information.
DIAG status LED
Shows the following states:
•
Green:
PTP-LOCK OK.
•
Off:
PTP-LOCK Fail.
See also
, on page 50 and
on page 91 for more information.
BOARD status LED Shows the following states:
•
Green:
PTP-SYNC OK. PTP being used and clocks are within the
accepted range.
•
Off:
PTP-SYNC Fail. PTP being used but clocks haven't
synchronized /- 1mS.
PTP status LED
Future use.
Summary of Contents for UCP-3901
Page 1: ...User Manual 13 03084 010 M00 AB 2020 10 27 UCP 3901 UNIFIED COMPUTE PROCESSOR FOR DENSITÉ ...
Page 18: ...18 Introduction Supported SFP28 Cartridges ...
Page 32: ...32 UCP 3901 Card Installation and Operation Remote control using RollCall ...
Page 36: ...36 Connections and Cabling Cabling to Support SMPTE ST 2022 7 with a UCP 3901 ...
Page 122: ...122 Essence Processing SDC SFP Configuration ...
Page 202: ...202 Maintenance Troubleshooting Keep Fiber Connections Clean ...