Set up PFR500 or PFR 600 network settings
23 January 2004
PVS 2000 Installation Guide
27
3. If the optional RAID Controller B is installed, perform the following steps, otherwise,
proceed to step 4.
a. Move the standard serial cable connector to the daisy chain cable connected to
to RAID Controller B.
b. Repeat the instructions for modifying network and SNMP settings in step 2 of
this procedure.
4. Exit Hyperterminal.
Now that the RAID controller network and SNMP settings are configured, you can
proceed to “Start NetCentral Lite monitoring software” on page 31.
Wait for reboot, plus 10
seconds, to allow the
Enclosure Services Interface
initialization to start.
Rebooting now for new system parameters to take effect
Ciprico Web Manager
Copyright Ciprico Inc. 2000
--------------------------------------------------------------------------
NETWORK INTERFACE PARAMETERS:
IP address on LAN is 192.168.0.11
LAN interface's subnet mask is 255.255.255.0
COMMUNICATION PARAMETERS:
Serial channels will use a baud rate of 9600
HARDWARE PARAMETERS:
This board's MAC Address is 0:20:46:11:15:81
APPLICATION PARAMETERS:
Boot Ciprico Network Server
Mail and SNMP notification will occur for Warnings and Critical
events.
SNMP TRAP CONFIGURATION:
TRAP COMMUNITY NAME 'public'
TRAP MANAGER #1 IP Address 192.168.0.10
After board is reset, start-up code will wait 10 seconds
--------------------------------------------------------------------------
To change any of this, press any key within 10 seconds
Wait for initialization, then
proceed to step 3 of this
procedure.
NOTE: If the network cable
is not connected, the console
stops at the message
“Waiting for Ethernet
Link...”. If you cannot
connect network cabling at
this time, cycle the power on
the RAID Controller chassis,
then proceed to step 3
following this table. You will
not be able to monitor
yourRAID chassis with
NetCentral, or update its
firmware.
Initializing Enclosure Services Interface......Done
Started Monitor
Started SNMP Agent
Started FTP Flash Loader
Started Web Server
Started Telnet Server
************************************************
* Ciprico Web Manager Network Server *
* Revision: 2.3.7 *
* Compiled: 01/23/02 00:28:24 CST *
************************************************
Ciprico#
Instructions
Text entered and displayed in terminal window
Summary of Contents for Profile XP PVS1000
Page 16: ...16 PVS2000 Installation Guide 23 February 2004 ...
Page 22: ...Create a video file system 22 PVS2000 Installation Guide 23 February 2004 ...
Page 28: ...Set up PFR500 or PFR600 network settings 28 PVS2000 Installation Guide 23 January 2004 ...
Page 44: ...Select an RS 422 control protocol 44 PVS2000 Installation Guide 23 February 2004 ...
Page 46: ...46 Grass Valley Product Support 23 February 2004 ...