ALARM E8
HEATING ANOMALY
DESCRIPTION ON DISPLAY
E8: Heating anomaly
DESCRIPTION
If TEMP1 reads a temperature higher than 25°C with respect to the set point, the cycle is
aborted and the display shows
“E8: Heating anomaly”.
This control is only performed with the cycle in progress and only in the heating phase. It is
NOT managed in the cooling phase.
If the temperature probe should brake or it is disconnected alarm E5 has priority over alarm
E8.
BUZZER ACTIVATION
The activation of the BUZZER is envisioned.
ALARM RESET
The alarm is removed only by switching the machine off and back on again.
WHAT TO CONTROL
Heating remote control switch, coil and power contacts.
TEMP1 temperature probe.
Loading the laundry and mist evacuation flue.
Change cycle with cycle in progress.
CORRECTIVE ACTION
Replace the heating remote control switch.
Check the connection cable, the sensitive element and the TEMP1 probe connector. If
necessary, replace the probe.
As explained in alarm E6 and E7 the laundry load must not exceed the nominal load and the
mist evacuation flue must respect the provisions envisioned.
Changing the cycle while the machine works is possible as long as the new selection envisions
a much lower temperature than the previous one and therefore the machine gives an alarm.
Makes the correct cycle start-up directly.
ALARM E9
HEATING TIME OUT
DESCRIPTION ON DISPLAY
E9: Heating time-out
DESCRIPTION
If the machine takes longer than that envisioned to reach the set point, the cycle is aborted
and the display shows “
E9: Heating time-out
”.
This control is only performed with the cycle in progress and only in the first heating phase,
i.e. until the first arrival at the set temperature. It is NOT managed in the heat adjustment or
cooling phase.
BUZZER ACTIVATION
The activation of the BUZZER is not envisioned.
ALARM RESET
The alarm is removed automatically when the temperature is reached.
WHAT TO CONTROL
Heating remote control switch, coil and power contacts.
TEMP1 temperature probe.
Loading the laundry and mist evacuation flue.
CORRECTIVE ACTION
Replace the heating remote control switch.
Check the connection cable, the sensitive element and the TEMP1 probe connector. Change
the probe if necessary.
As explained in alarm E6 and alarm E7 the laundry load must no exceed the nominal load and
the mist evacuation flue must respect the envisioned prescriptions.