11
7. SPACE NECESSARY FOR THE INSTALLATION,
USE AND MAINTENANCE OF THE MACHINE
The washing machine must have the minimum space indicated
in figure 1 available:
1) Electric power supply line with an automatic differential
switch and magnet circuit breaker switch installed at
the beginning.
2) Interlocked electric socket with line fuses and manual
multiple-pole switch (not supplied).
3) Electric power supply plug (not supplied).
4) Mechanical filter for steam supply inlet (EBV models
only, not supplied).
5) Solenoid valve for steam supply inlet (EBV models only,
not supplied).
6) Condensate discharger (EBV models only; not
supplied).
7) Steam supply line with recommended pressure between
4 and 6 bar (EBV models only).
8) Condensate recovery line (EBV models only).
9) Steam supply line gate valve (EBV models only, not
supplied).
10) Condensate recovery line gate valve (EBV models only,
not supplied).
11) Gas supply line (EBG models only, See plate data for the
type of gas and power supply pressure).
12) Gas supply closure gate valve (EBG models only, not
supplied).
13) Mist evacuation flue diam. 150mm with smooth internal
surface.
14) Gas supply connection, diam. ½”.
15) Electric power supply input PG16.
16) ¾”steam inlet (EBV models only).
17) ¾” condensate outlet (EBV models only).
18) Safety thermostat reset button.
19) Optional buttons for special versions (see use and
maintenance manual).
20) Inspection window with 180° opening.
21) Handle for opening filter hatch in the discharge
channel.
* The position of the automatic isolator switch must be such
to be easily activated by the operator in an EMERGENCY
situation.
Summary of Contents for EB10