1.  PREMISE AND WARRANTY

1.1  PREMISE

We would like to thank you for the purchase of our machine.
We  are  sure  you  will  be  satisfied  and  will  obtain  the  best 
guarantees if you follow the indications given in this manual 
carefully.
We must also inform you that for any claims or observations 
the reference text is the original one in the manufacturer’s 
language i.e. Italian

1.2  PRESCRIPTIONS AND RECOMMENDATIONS
This appliance cannot be used by persons (including children) 

with reduced physical, sensorial, mental capacities or with 
little  experience  or  knowledge  unless  they  have  been 
examined or trained regarding the use of the appliance by 
suitably trained staff that is responsible for his/their safety.
This  manual  must  be  considered  an  integral  part  of  the 
appliance and must be kept with the same, accompanying it 
if ownership changes.

Deactivate  the  appliance  in  the  case  of  breakdown  and/or 
bad functioning.
During use, cleaning and maintenance, attention must be paid 
not to access moving parts with tools or the hands (motors, 
belts, chains and gears).
In the case of accidents, the manufacturer does not assume 
any responsibility for damage to the operator or other persons 
that take place during use, cleaning and maintenance of the 
appliance.
For  the  washing  machine,  pay  attention  not  to  open  the 
dispenser during machine functioning.

Pay particular attention to all hot appliance parts, such as 
connection  pipes  and  supply  fluid  discharge  pipes  usually 
positioned in the rear, door glass and, where present, mist 
evacuation flues.

The appliance has been designed to treat textiles according 
to  the  indications  stated  on  the  labels  of  the  garments 
themselves.  Only  treat  garments,  household  linens  and 
fabrics for everyday use.
Do not treat items that have been in contact with chemical or 
inflammable products. First wash by hand a dry them in the 
open air to allow these substances to evaporate completely.
The use of any electric or electronic equipment requires that 
several fundamental rules are complied with. In particular:

Do not touch the appliance with wet or humid hands or 

• 

feet.
Do not use the appliance barefoot.

• 

Do  not  leave  the  appliance  exposed  to  atmospheric 

• 

agents (rain, salt, sea salt etc.).
Do  not  allow  children  to  use  the  appliance  or  unable 

• 

persons  to  use  the  appliance  without  suitable 

surveillance.
Do not smoke in proximity of the appliance during use.

• 

Do not remove or by-pass safety devices.

• 

Never  use  direct  or  indirect  jets  of  water  on  the 

• 

machine, pay attention not to install it in proximity of 
zones where this is possible.

DO  NOT  use  the  appliance  if  you  are  not  trained  to 

• 

do so.

ANY OTHER USE THAT IS NOT EXPRESSLY INDICATED MUST 
BE CONSIDERED DANGEROUS.
THE MANUFACTURER CANNOT BE CONSIDERED LIABLE FOR 
ANY  DAMAGE  DERIVING  FROM  IMPROPER,  INCORRECT 
AND  UNREASONABLE  USE  OR  ANY  USE  NOT  STATED  IN 
THIS MANUAL.

1.2.1  SPECIFICATIONS FOR MODELS WITH GAS HEATING

1.2.1.1  GENERAL RECOMMENDATIONS

Read  the  installation  technical  instructions  before 

• 

installing the appliance.
Read the instructions regarding use before switching the 

• 

appliance on.
The appliance must only be installed in an environment 

• 

that satisfies the necessary ventilation requisites.

The user of the appliance must not tamper with the sealed 
machine components.
For  any  adjustments  or  intervention  on  any  component 
relative  to  the  gas  circuit,  contact  a  qualified  technician, 
enabled for the intervention.
The  removal  or  alteration  of  the  machine  seals  causes  the 
appliance warranty to become void.

1.2.1.2  INSTALLATION

The  installation  of  the  machine  with  gas  heating  and  the 
commissioning  of  the  appliance  must  be  performed  by  a 
qualified, enabled technician that will check the correctness 
of installation and check the combustion parameters with the 
aid of suitable instruments.

If adjustments are necessary on sealed parts, for calibration, 
change of gas type or other reason, 
they must only be performed by enabled technicians that, at 
the end of the adjustment operations, will restore the seals 
of the adjusted parts and issue a regular report that must be 
kept with the manual.

The equipment necessary for the change of the type of gas 
family is supplied with the appliance. It is made up of:

-  Diaphragm for gas of the second family and installation in 

France and Belgium (G20/G25).

-   Calibrated nozzle set for the various gas groups (see table 

USE AND MAINTENANCE

Summary of Contents for EB10

Page 1: ...grandimpianti Industrial Laundry Equipment Via Masiere 211 C 32037 Sospirolo bl Italy USE AND MAINTENANCE DRYER EB10 EB15 G400 DRY ELECTRONIC CONTROL...

Page 2: ...s or feet Do not use the appliance barefoot Do not leave the appliance exposed to atmospheric agents rain salt sea salt etc Do not allow children to use the appliance or unable persons to use the appl...

Page 3: ...anual In the case of interventions on the machine the company recommends the use of original spare parts To order consult the relative paragraph at the end of the manual The descriptions and illustrat...

Page 4: ...EXTRACTORFANISCONNECTEDWITHTHEPHASES INCORRECT REVERSE CYCLIC DIRECTION EXTRACTION WILL BE INSUFFICIENT FOR MACHINE FUNCTIONING INFORM THE CUSTOMER THEUSER OR THE TECHNICAL MANAGEROFTHELAUNDRYPLANTOFT...

Page 5: ...t of lighting in the work place for other countries refer to individual national laws Keep a distance of at least 10cm in air from all parts of furniture that can be considered flammable 5 2 CONNECTIO...

Page 6: ...of the steam plant Other elements such as pipe bleeding devices heat exchangers pumps for condensate rising superheaters and support lungs must be used depending on the type of plant and dryer perfor...

Page 7: ...A heavier load can compromise the air circuit and is NOT allowed The filter in the discharge channel is an integral part of the appliance This MUST NOT be allowed to function without the above mention...

Page 8: ...ER TYPES OF GAS Replace the nozzle placed on the right of the burner checking that the diameter stated in the new nozzle that is to be mounted corresponds to the following table see exploded diagram g...

Page 9: ...f the gas valve outlet flange insert the diaphragm as shown in the illustrations B along with the relative joint C tighten the new flange pack B C using the longest supplied screws N B payattentiontot...

Page 10: ...related to the effective load in the machine ENTER BUTTON confirmation of the value inserted in the programming of the optional parameters PLUS BUTTON to increase values MINUS BUTTON to decrease valu...

Page 11: ...EBV models only 8 Condensate recovery line EBV models only 9 Steam supply line gate valve EBV models only not supplied 10 Condensate recovery line gate valve EBV models only not supplied 11 Gas suppl...

Page 12: ...and press start which will alternate until the door is closed when the display will remain fixed on press start WhentheSTARTbuttonispressedthecalibrationphaseisactivated with drum rotation as if it we...

Page 13: ...h Heating After the 2 min the writing switches over to Drying Heating time to decrease resistance icon min xxx C xxx Cooling time to decrease cooling icon min xxx or C xxx KMODE pressed CYCLE IN PROGR...

Page 14: ...NFIRMATION USING KENT CYCLE IN STAND BY 3 SERVICE 3 1 LANGUAGE 3 2 TYPE OF DEGREES 3 3 OUTPUT PROBES 3 4 MOTOR 3 5 TEMPERATURE 3 6 ECONOMY FUNCTION 3 7 HEATING TABLE 3 8 MACHINE TYPE 3 9 SELF SERVICE...

Page 15: ...YES NO CYCLE 35 YES NO MACHINE PARAMETERS 1 2 START DELAY disabled enabled START delay 00h 00 min 23h 59 min definition 1 min MACHINE PARAMETERS 1 3 BUZZER YES NO MACHINE PARAMETERS 1 4 ANTI FOLD DRUM...

Page 16: ...10 C HEATING POWER 70 100 COOL TEMPERATURE 0 100 C TIME 0 20min RELATIVE HUMIDITY WITH HUMIDITY PROBE YES NO PERCENTAGE RH 0 50 DELTA T1 T2 0 100 C MOTOR LEFT RIGHT ACTIVATION 0 255 sec PAUSE 0 255 se...

Page 17: ...d by acting on the START STOP button after this operation the display on the control panel shows the various phases of the selected cycle At the same time the START STOP button is pressed the time sta...

Page 18: ...t parameters of the machine All modifications made in this way WILL NOT BE MEMORISED in the end cycle board The first time the MODE button is pressed the display shows the real temperature and that se...

Page 19: ...e damaged irreparably The manufacturer is NOT liable for incorrect and improper use of the Smart Card reader present in the machine Contact the dealer or the after sales service if machine programmin...

Page 20: ...ppliance preferably locked in a cabinet Do not obstruct openings of slots used for extraction of removal of heat Keep a suitable distance between the machine and walls or other objects 9 SAFETY PROCED...

Page 21: ...until the door is closed The timers behave as described below Case 1 For the first 30 seconds of door opening countdown is NOT continued However it re starts regularly after 30seconds If the door is...

Page 22: ...rner management control unit This alarm is only managed during heating ignition therefore with the HEAT relay at ON and the gas supply powered This alarm is delayed by 12 seconds with respect to the h...

Page 23: ...mist evacuation flue This flue must be clean with least bends possible and without long horizontal tracts There must be NO downward tracts or siphons ALARM E5 SAFETY THERMOSTAT DESCRIPTION ON DISPLAY...

Page 24: ...ne The appliance has been designed for a damp laundry load at 50 The weight of the load must therefore refer to this condition and NOT dry laundry and successively washed and spun ALARM E7 AIR CIRCUIT...

Page 25: ...ions envisioned Changing the cycle while the machine works is possible as long as the new selection envisions a much lower temperature than the previous one and therefore the machine gives an alarm Ma...

Page 26: ...TION Connect the appliance to a mains electric power supply that guarantees the correct power supply voltage Optimise the load of laundry ALARM MOTOR PROTECTION INTERVENTION WITH ALARMS NOT IN AUTORES...

Page 27: ...home a beep must be heard to confirm No alarm has intervened see Alarms Functioning The load of laundry does not exceed drum capacity see technical data table according to the type of dryer Make sure...

Page 28: ...ance model and the serial number both of these can be found on the plate on the rear 10 3 1 MONTHLY CHECK Check all safety devices therefore Check that the safety thermostat is in good working order a...

Page 29: ...y n 151 regarding Implementation of Directives 2002 95 CE 2002 96 CE and 2003 108 CE relative to the reduction of use of dangerous substances in electric and electronic appliances as well as the dispo...

Page 30: ...1 48 5 Delicate 25 90 3 95 2 50 60 1 49 6 Normal dynamic 30 135 4 95 2 50 30 0 5 48 7 Medium dynamic 35 135 4 95 2 50 30 0 5 47 8 Intensive 25 140 5 95 3 50 25 0 5 48 9 Heavy intensive 30 140 5 95 3 5...

Page 31: ...ic 30 100 4 95 2 50 25 0 5 48 5 Delicate 30 90 3 95 2 50 30 0 5 48 DRYER 10 15kg gas COIN OPERATED DRYING Cooling Motor Cycle number Cycle name Time Temperature Hysterisis Power Time Temperature Work...

Page 32: ...5 Quilted jackets 30 120 40 50 3 6 Windcheaters 20 130 40 46 5 the speed must always be calibrated manually depending on the effective load of laundry To have less mechanical action increase the numbe...

Page 33: ...ng for the multiple of time programmed means that the time must just be lengthened without the cooling phase in between every time For example in the case indicated above regarding 3 payments the heat...

Page 34: ...an be used for the successive cycle The maximum credit i e the maximum value that can be accumulated is 20 00 NOTE See also coin operation setting inthe previous paragraph In both cases it must be pos...

Page 35: ...ASPIRATION ANSCHLUSS ABASAUGUNGSMOTOR CONEXION MOTOR ASPIRACION 12000W 230 1 Schema di potenza collegamento 230 1 50 230 1 50 UK 230 3 50 60 400 3 50 60 440 3 60 K4 K4 K4 EBE10 EBE15 DRIVE K1 K1 1 2...

Page 36: ...oprocessor flash programming Plate2 LD1 LD2 LD3 LD4 LD5 To power board IN1 RL1 RL2 RL3 RL4 RL5 12CN3 11CN3 13CN3 15CN3 14CN3 14 15 12 13 26 0 16 Vac 1CN5A 4CN5A 57CN5A 6CN5A N N N L3 L3 T1 7 7A 4CN5A...

Page 37: ...M4 COIN OPERATION MICRO SWITCH M5 FILTER SAFETY DEVICE MICRO SWITCH PF1 CONTACT 1 MUSHROOM SHAPED BUTTON PF2 CONTACT 2 MUSHROOM SHAPED BUTTON Plate1 G400 CONTROL LOGIC BOARD Plate 2 POWER ACTUATOR BOA...

Page 38: ...38...

Page 39: ...E 10 6 2 DESCRIPTION OF THE PUSH BUTTON CONTROL PANEL 10 6 3 COMPLETE RANGE OF THE APPLICATIONS 10 6 4 INFORMATION REGARDING THE ELECTRIC PLANT 10 7 SPACE NECESSARY FOR THE INSTALLATION USE AND MAINTE...

Page 40: ...TEPPER 33 13 3 2 EXTERNAL COIN OPERATION OR WITH CENTRAL PAYMENT UNIT 33 13 3 3 ELECTONIC COIN OPERATION ON THE MACHINE 33 13 4 SET CYCLE COST 33 13 4 1 COIN OPERATION WITH STEPPER 33 13 4 2 EXTERNAL...

Page 41: ...CHILD PLACA DE CARACTER STICAS RIVENDITORE DISTRIBUTOR REVENDEUR VERTRIEB REVENDEDOR ASSISTENZA TECNICA AFTER SALES SERVICE SERVICE APRES VENTE KUNDENDIENST SERVICIO DE ASISTENCIA T CNICA MODELLO MODE...

Reviews: