background image

19

reset and the memory cleaned.

5.  On insertion of the smartcard, as a third option as well 

as that of choosing from downloading the data or saving 
them in the card (right or left arrow)it is also possible 
to  format  the  smartcard;  the  display  will  show  “Reset 
card” and the option must be confirmed using ENTER. A 
formatted card can therefore be managed for washing 
machines and dryers. As the name of the presets saved, 
the formatted card gives a series of “- - - - - - - - - “.

 

NOTE  only  a  part  of  the  manageable  presets  can  be 
saved and those formatted or empty will be identified 
with “- - - - - - - - -“

.

6.  The name of the saved preset is that of the 

2.13 “large 

comment”

 function inserted from the SERVICE menu.

8.5.2  TRANSFER OF THE FIRMWARE

8.5.2.1  UPLOADING  NEW  FIRMWARE  FROM  THE 

SMARTCARD

The  firmware  uploading  operation  takes  place  by  inserting 
the smartcard with the machine off and after having supplied 
voltage to the machine the system will act as follows:

1.  Incorrect card: the display will indicate “

card not valid

” 

also adding an icon with the same message, inviting the 
user to remove the card. On removal, the machine will 
go  back  to  previous  conditions.  In  this  phase  a  cycles 
card is considered NOT correct.

2.  Correct card: we will have the “

DOWNLOAD Firmware

” 

information with the arrows from the machine card. On 
conclusion  of  the  operation  the  display  will  show  the 
card by the usual icon.

If the firmware card is inserted with the machine on in cycle 
start stand-by conditions, the G400 DRY will activate the card 
recognition  routine  and  the  display  will  show  “

Firmware 

card

”, without allowing any operation. 

8.5.2.2  COPYING THE FIRMWARE INTO THE SMARTCARD

The appliance must be on by pressing the SEL, ECONOMY and 
START/STOP buttons together.
At this point the display will show “

UPLOAD Firmware

” and 

the icon indicates to insert the firmware card (128kB).
When transfer is completed the icon relative to removal of the 
smartcard switches on and once the card has been removed it 
is possible to insert another in order to repeat the operation 
and so on, thus creating a series of identical smartcards.
The machine must be switched off and on again to return to 
standard display.

ATTENTION!

•  Do not try to read or program the machine using the 

SMARTCARDS  that  are  different  to  the  original  one 
(cash card, credit card, video hire card etc.) as it would 
e damaged irreparably. The manufacturer is NOT liable 
for incorrect and improper use of the Smart Card reader 

present in the machine.

•  Contact the dealer or the after-sales service if machine 

programming must be modified using this system.

8.6  RECOMMENDATIONS FOR USING THE MACHINE

•  Do  not  put  laundry  into  the  machine  that  has  been 

cleaned,  wet,  washed  or  stained  with  flammable  or 
explosive materials, first proceed with a washing cycle.  
Read the instructions before using the appliance in order 
to prevent injury to persons/damage to objects.

•  Keep  solvents  and  inflammable  liquids  away  from  the 

appliance. Keep them in a dry, well-aired place that is 
not accessible to unauthorised persons.

•  Keep cleaning and waxing products out of the reach of 

children and locked in a safe place.

•  Only  use  suitable  textiles  in  the  dryer  and  that  have 

been previously washed.

•  Check  the  labels  on  the  garments,  checking  that  they 

can go into the dryer.

•  Do not allow children to play near or approach the dryer, 

contact with the drum or laundry during functioning can 
cause burns, contact a doctor if necessary.

•  Do not smoke in proximity of the dryer during use.
•  Do not remove or by-pass safety devices.
•  Any  interventions  or  maintenance  must  only  be 

performed by authorised staff.

•  Do  not  touch  the  glass  during  functioning  as  it  may 

cause burns.

•  Do not switch the machine off if the temperature in the 

drum exceeds 50°C.

•  If  there  is  a  power  cut  during  functioning,  open  the 

door: when the current returns, start the appliance as 
soon as possible.

•  In  order  to  reduce  the  global  energy  consumption  of 

your laundry it is recommended to prepare the laundry 
to be ironed with residual humidity of 5-20%

•  Items  that  have  not  been  previously  spun  cannot  be 

dried.  The  maximum  humidity  of  the  laundry  before 
being dried must be 105%. If necessary, halve the load 
per cycle.

•  Do  not  wait  for  the  dryer  to  cool  completely  before 

starting a new cycle.

•  Before shifting, carrying out an intervention and at the 

end of working, switch the electric power supply off and 
disconnect the plug and socket. Do not pull the cable. 
Close the gas and steam cocks.

•  After any intervention, make sure that the machine has 

been restored correctly and that the parts that protect 
access to the mechanical and live parts are organised.

•  In order to measure the residual humidity of the laundry 

weigh it before washing and after drying. The difference 
of these values is the amount of water present in the 
laundry, which divided by the original weight gives the 
residual humidity.

Summary of Contents for EB10

Page 1: ...grandimpianti Industrial Laundry Equipment Via Masiere 211 C 32037 Sospirolo bl Italy USE AND MAINTENANCE DRYER EB10 EB15 G400 DRY ELECTRONIC CONTROL...

Page 2: ...s or feet Do not use the appliance barefoot Do not leave the appliance exposed to atmospheric agents rain salt sea salt etc Do not allow children to use the appliance or unable persons to use the appl...

Page 3: ...anual In the case of interventions on the machine the company recommends the use of original spare parts To order consult the relative paragraph at the end of the manual The descriptions and illustrat...

Page 4: ...EXTRACTORFANISCONNECTEDWITHTHEPHASES INCORRECT REVERSE CYCLIC DIRECTION EXTRACTION WILL BE INSUFFICIENT FOR MACHINE FUNCTIONING INFORM THE CUSTOMER THEUSER OR THE TECHNICAL MANAGEROFTHELAUNDRYPLANTOFT...

Page 5: ...t of lighting in the work place for other countries refer to individual national laws Keep a distance of at least 10cm in air from all parts of furniture that can be considered flammable 5 2 CONNECTIO...

Page 6: ...of the steam plant Other elements such as pipe bleeding devices heat exchangers pumps for condensate rising superheaters and support lungs must be used depending on the type of plant and dryer perfor...

Page 7: ...A heavier load can compromise the air circuit and is NOT allowed The filter in the discharge channel is an integral part of the appliance This MUST NOT be allowed to function without the above mention...

Page 8: ...ER TYPES OF GAS Replace the nozzle placed on the right of the burner checking that the diameter stated in the new nozzle that is to be mounted corresponds to the following table see exploded diagram g...

Page 9: ...f the gas valve outlet flange insert the diaphragm as shown in the illustrations B along with the relative joint C tighten the new flange pack B C using the longest supplied screws N B payattentiontot...

Page 10: ...related to the effective load in the machine ENTER BUTTON confirmation of the value inserted in the programming of the optional parameters PLUS BUTTON to increase values MINUS BUTTON to decrease valu...

Page 11: ...EBV models only 8 Condensate recovery line EBV models only 9 Steam supply line gate valve EBV models only not supplied 10 Condensate recovery line gate valve EBV models only not supplied 11 Gas suppl...

Page 12: ...and press start which will alternate until the door is closed when the display will remain fixed on press start WhentheSTARTbuttonispressedthecalibrationphaseisactivated with drum rotation as if it we...

Page 13: ...h Heating After the 2 min the writing switches over to Drying Heating time to decrease resistance icon min xxx C xxx Cooling time to decrease cooling icon min xxx or C xxx KMODE pressed CYCLE IN PROGR...

Page 14: ...NFIRMATION USING KENT CYCLE IN STAND BY 3 SERVICE 3 1 LANGUAGE 3 2 TYPE OF DEGREES 3 3 OUTPUT PROBES 3 4 MOTOR 3 5 TEMPERATURE 3 6 ECONOMY FUNCTION 3 7 HEATING TABLE 3 8 MACHINE TYPE 3 9 SELF SERVICE...

Page 15: ...YES NO CYCLE 35 YES NO MACHINE PARAMETERS 1 2 START DELAY disabled enabled START delay 00h 00 min 23h 59 min definition 1 min MACHINE PARAMETERS 1 3 BUZZER YES NO MACHINE PARAMETERS 1 4 ANTI FOLD DRUM...

Page 16: ...10 C HEATING POWER 70 100 COOL TEMPERATURE 0 100 C TIME 0 20min RELATIVE HUMIDITY WITH HUMIDITY PROBE YES NO PERCENTAGE RH 0 50 DELTA T1 T2 0 100 C MOTOR LEFT RIGHT ACTIVATION 0 255 sec PAUSE 0 255 se...

Page 17: ...d by acting on the START STOP button after this operation the display on the control panel shows the various phases of the selected cycle At the same time the START STOP button is pressed the time sta...

Page 18: ...t parameters of the machine All modifications made in this way WILL NOT BE MEMORISED in the end cycle board The first time the MODE button is pressed the display shows the real temperature and that se...

Page 19: ...e damaged irreparably The manufacturer is NOT liable for incorrect and improper use of the Smart Card reader present in the machine Contact the dealer or the after sales service if machine programmin...

Page 20: ...ppliance preferably locked in a cabinet Do not obstruct openings of slots used for extraction of removal of heat Keep a suitable distance between the machine and walls or other objects 9 SAFETY PROCED...

Page 21: ...until the door is closed The timers behave as described below Case 1 For the first 30 seconds of door opening countdown is NOT continued However it re starts regularly after 30seconds If the door is...

Page 22: ...rner management control unit This alarm is only managed during heating ignition therefore with the HEAT relay at ON and the gas supply powered This alarm is delayed by 12 seconds with respect to the h...

Page 23: ...mist evacuation flue This flue must be clean with least bends possible and without long horizontal tracts There must be NO downward tracts or siphons ALARM E5 SAFETY THERMOSTAT DESCRIPTION ON DISPLAY...

Page 24: ...ne The appliance has been designed for a damp laundry load at 50 The weight of the load must therefore refer to this condition and NOT dry laundry and successively washed and spun ALARM E7 AIR CIRCUIT...

Page 25: ...ions envisioned Changing the cycle while the machine works is possible as long as the new selection envisions a much lower temperature than the previous one and therefore the machine gives an alarm Ma...

Page 26: ...TION Connect the appliance to a mains electric power supply that guarantees the correct power supply voltage Optimise the load of laundry ALARM MOTOR PROTECTION INTERVENTION WITH ALARMS NOT IN AUTORES...

Page 27: ...home a beep must be heard to confirm No alarm has intervened see Alarms Functioning The load of laundry does not exceed drum capacity see technical data table according to the type of dryer Make sure...

Page 28: ...ance model and the serial number both of these can be found on the plate on the rear 10 3 1 MONTHLY CHECK Check all safety devices therefore Check that the safety thermostat is in good working order a...

Page 29: ...y n 151 regarding Implementation of Directives 2002 95 CE 2002 96 CE and 2003 108 CE relative to the reduction of use of dangerous substances in electric and electronic appliances as well as the dispo...

Page 30: ...1 48 5 Delicate 25 90 3 95 2 50 60 1 49 6 Normal dynamic 30 135 4 95 2 50 30 0 5 48 7 Medium dynamic 35 135 4 95 2 50 30 0 5 47 8 Intensive 25 140 5 95 3 50 25 0 5 48 9 Heavy intensive 30 140 5 95 3 5...

Page 31: ...ic 30 100 4 95 2 50 25 0 5 48 5 Delicate 30 90 3 95 2 50 30 0 5 48 DRYER 10 15kg gas COIN OPERATED DRYING Cooling Motor Cycle number Cycle name Time Temperature Hysterisis Power Time Temperature Work...

Page 32: ...5 Quilted jackets 30 120 40 50 3 6 Windcheaters 20 130 40 46 5 the speed must always be calibrated manually depending on the effective load of laundry To have less mechanical action increase the numbe...

Page 33: ...ng for the multiple of time programmed means that the time must just be lengthened without the cooling phase in between every time For example in the case indicated above regarding 3 payments the heat...

Page 34: ...an be used for the successive cycle The maximum credit i e the maximum value that can be accumulated is 20 00 NOTE See also coin operation setting inthe previous paragraph In both cases it must be pos...

Page 35: ...ASPIRATION ANSCHLUSS ABASAUGUNGSMOTOR CONEXION MOTOR ASPIRACION 12000W 230 1 Schema di potenza collegamento 230 1 50 230 1 50 UK 230 3 50 60 400 3 50 60 440 3 60 K4 K4 K4 EBE10 EBE15 DRIVE K1 K1 1 2...

Page 36: ...oprocessor flash programming Plate2 LD1 LD2 LD3 LD4 LD5 To power board IN1 RL1 RL2 RL3 RL4 RL5 12CN3 11CN3 13CN3 15CN3 14CN3 14 15 12 13 26 0 16 Vac 1CN5A 4CN5A 57CN5A 6CN5A N N N L3 L3 T1 7 7A 4CN5A...

Page 37: ...M4 COIN OPERATION MICRO SWITCH M5 FILTER SAFETY DEVICE MICRO SWITCH PF1 CONTACT 1 MUSHROOM SHAPED BUTTON PF2 CONTACT 2 MUSHROOM SHAPED BUTTON Plate1 G400 CONTROL LOGIC BOARD Plate 2 POWER ACTUATOR BOA...

Page 38: ...38...

Page 39: ...E 10 6 2 DESCRIPTION OF THE PUSH BUTTON CONTROL PANEL 10 6 3 COMPLETE RANGE OF THE APPLICATIONS 10 6 4 INFORMATION REGARDING THE ELECTRIC PLANT 10 7 SPACE NECESSARY FOR THE INSTALLATION USE AND MAINTE...

Page 40: ...TEPPER 33 13 3 2 EXTERNAL COIN OPERATION OR WITH CENTRAL PAYMENT UNIT 33 13 3 3 ELECTONIC COIN OPERATION ON THE MACHINE 33 13 4 SET CYCLE COST 33 13 4 1 COIN OPERATION WITH STEPPER 33 13 4 2 EXTERNAL...

Page 41: ...CHILD PLACA DE CARACTER STICAS RIVENDITORE DISTRIBUTOR REVENDEUR VERTRIEB REVENDEDOR ASSISTENZA TECNICA AFTER SALES SERVICE SERVICE APRES VENTE KUNDENDIENST SERVICIO DE ASISTENCIA T CNICA MODELLO MODE...

Reviews: