8.  DRYER FUNCTIONING

8.1  PREMISE

Check  that  the  gas  and  steam  gate  valves  (power  supply 
and condensate exhaust) for the machines with this type of 
heating are open. 
Switch-over  the  automatic  magnet  circuit  breaker  on  the 
wall  to  the  ON  position.  At  this  point  if  the  door  is  closed, 
the  appliance  is  in  stand-by  for  start  to  be  given  using  the 
relative button (START/STOP) also positioned on the front of 
the machine. 

8.1.1  COMMISSIONING: PRESSURE SWITCH CALIBRATION

On  commissioning  of  the  appliance  the  pressure  switch 
zero value MUST be calibrated. This determines cleanliness 
of the filter and this MUST be performed with the machine 
installed and with clean filter and empty drum.

The sequence of actions to be performed for calibration of the 
pressure switch is the following.
With the machine not in cycle and the door open press the START 
button 10 times successively in 15 seconds.
The  display  signals  “

Calibration

”  followed  by  “

close  door  and 

press start

” which will alternate until the door is closed, when the 

display will remain fixed on “

press start

”.

When the START button is pressed the calibration phase is activated 
with drum rotation, as if it were a normal drying function, without 
however switching heating on. The display will show “

Calibration 

in progress

” and the value read by the pressure switch.

ATTENTION!

•  This value is only the fruit of a calculation and has no 

reference to the length of the flue or any particularity 
of the installation.

•  The  blocked  filter  alarm  is  NOT  active  during  this 

procedure.

Calibration  lasts  for  20  seconds  and  when  the  procedure  is 
finished the display indicates “

Calibration performed

” for 5 

seconds, showing the new data on the screen. After which the 
display goes back to normal.

ATTENTION!

•  No button can be used during calibration. Every alarm 

intervention aborts the procedure.

•  If the door open status is read during the procedure, 

the  alarm  E2  is  activated  and  calibration  must  be 

carried out again.

8.1.2  CYCLE SELECTION AND START

For the selection operations, cycle start and programming of 
the  optional  parameters,  refer  to  the  block  diagram  shown 
below.

Summary of Contents for EB10

Page 1: ...grandimpianti Industrial Laundry Equipment Via Masiere 211 C 32037 Sospirolo bl Italy USE AND MAINTENANCE DRYER EB10 EB15 G400 DRY ELECTRONIC CONTROL...

Page 2: ...s or feet Do not use the appliance barefoot Do not leave the appliance exposed to atmospheric agents rain salt sea salt etc Do not allow children to use the appliance or unable persons to use the appl...

Page 3: ...anual In the case of interventions on the machine the company recommends the use of original spare parts To order consult the relative paragraph at the end of the manual The descriptions and illustrat...

Page 4: ...EXTRACTORFANISCONNECTEDWITHTHEPHASES INCORRECT REVERSE CYCLIC DIRECTION EXTRACTION WILL BE INSUFFICIENT FOR MACHINE FUNCTIONING INFORM THE CUSTOMER THEUSER OR THE TECHNICAL MANAGEROFTHELAUNDRYPLANTOFT...

Page 5: ...t of lighting in the work place for other countries refer to individual national laws Keep a distance of at least 10cm in air from all parts of furniture that can be considered flammable 5 2 CONNECTIO...

Page 6: ...of the steam plant Other elements such as pipe bleeding devices heat exchangers pumps for condensate rising superheaters and support lungs must be used depending on the type of plant and dryer perfor...

Page 7: ...A heavier load can compromise the air circuit and is NOT allowed The filter in the discharge channel is an integral part of the appliance This MUST NOT be allowed to function without the above mention...

Page 8: ...ER TYPES OF GAS Replace the nozzle placed on the right of the burner checking that the diameter stated in the new nozzle that is to be mounted corresponds to the following table see exploded diagram g...

Page 9: ...f the gas valve outlet flange insert the diaphragm as shown in the illustrations B along with the relative joint C tighten the new flange pack B C using the longest supplied screws N B payattentiontot...

Page 10: ...related to the effective load in the machine ENTER BUTTON confirmation of the value inserted in the programming of the optional parameters PLUS BUTTON to increase values MINUS BUTTON to decrease valu...

Page 11: ...EBV models only 8 Condensate recovery line EBV models only 9 Steam supply line gate valve EBV models only not supplied 10 Condensate recovery line gate valve EBV models only not supplied 11 Gas suppl...

Page 12: ...and press start which will alternate until the door is closed when the display will remain fixed on press start WhentheSTARTbuttonispressedthecalibrationphaseisactivated with drum rotation as if it we...

Page 13: ...h Heating After the 2 min the writing switches over to Drying Heating time to decrease resistance icon min xxx C xxx Cooling time to decrease cooling icon min xxx or C xxx KMODE pressed CYCLE IN PROGR...

Page 14: ...NFIRMATION USING KENT CYCLE IN STAND BY 3 SERVICE 3 1 LANGUAGE 3 2 TYPE OF DEGREES 3 3 OUTPUT PROBES 3 4 MOTOR 3 5 TEMPERATURE 3 6 ECONOMY FUNCTION 3 7 HEATING TABLE 3 8 MACHINE TYPE 3 9 SELF SERVICE...

Page 15: ...YES NO CYCLE 35 YES NO MACHINE PARAMETERS 1 2 START DELAY disabled enabled START delay 00h 00 min 23h 59 min definition 1 min MACHINE PARAMETERS 1 3 BUZZER YES NO MACHINE PARAMETERS 1 4 ANTI FOLD DRUM...

Page 16: ...10 C HEATING POWER 70 100 COOL TEMPERATURE 0 100 C TIME 0 20min RELATIVE HUMIDITY WITH HUMIDITY PROBE YES NO PERCENTAGE RH 0 50 DELTA T1 T2 0 100 C MOTOR LEFT RIGHT ACTIVATION 0 255 sec PAUSE 0 255 se...

Page 17: ...d by acting on the START STOP button after this operation the display on the control panel shows the various phases of the selected cycle At the same time the START STOP button is pressed the time sta...

Page 18: ...t parameters of the machine All modifications made in this way WILL NOT BE MEMORISED in the end cycle board The first time the MODE button is pressed the display shows the real temperature and that se...

Page 19: ...e damaged irreparably The manufacturer is NOT liable for incorrect and improper use of the Smart Card reader present in the machine Contact the dealer or the after sales service if machine programmin...

Page 20: ...ppliance preferably locked in a cabinet Do not obstruct openings of slots used for extraction of removal of heat Keep a suitable distance between the machine and walls or other objects 9 SAFETY PROCED...

Page 21: ...until the door is closed The timers behave as described below Case 1 For the first 30 seconds of door opening countdown is NOT continued However it re starts regularly after 30seconds If the door is...

Page 22: ...rner management control unit This alarm is only managed during heating ignition therefore with the HEAT relay at ON and the gas supply powered This alarm is delayed by 12 seconds with respect to the h...

Page 23: ...mist evacuation flue This flue must be clean with least bends possible and without long horizontal tracts There must be NO downward tracts or siphons ALARM E5 SAFETY THERMOSTAT DESCRIPTION ON DISPLAY...

Page 24: ...ne The appliance has been designed for a damp laundry load at 50 The weight of the load must therefore refer to this condition and NOT dry laundry and successively washed and spun ALARM E7 AIR CIRCUIT...

Page 25: ...ions envisioned Changing the cycle while the machine works is possible as long as the new selection envisions a much lower temperature than the previous one and therefore the machine gives an alarm Ma...

Page 26: ...TION Connect the appliance to a mains electric power supply that guarantees the correct power supply voltage Optimise the load of laundry ALARM MOTOR PROTECTION INTERVENTION WITH ALARMS NOT IN AUTORES...

Page 27: ...home a beep must be heard to confirm No alarm has intervened see Alarms Functioning The load of laundry does not exceed drum capacity see technical data table according to the type of dryer Make sure...

Page 28: ...ance model and the serial number both of these can be found on the plate on the rear 10 3 1 MONTHLY CHECK Check all safety devices therefore Check that the safety thermostat is in good working order a...

Page 29: ...y n 151 regarding Implementation of Directives 2002 95 CE 2002 96 CE and 2003 108 CE relative to the reduction of use of dangerous substances in electric and electronic appliances as well as the dispo...

Page 30: ...1 48 5 Delicate 25 90 3 95 2 50 60 1 49 6 Normal dynamic 30 135 4 95 2 50 30 0 5 48 7 Medium dynamic 35 135 4 95 2 50 30 0 5 47 8 Intensive 25 140 5 95 3 50 25 0 5 48 9 Heavy intensive 30 140 5 95 3 5...

Page 31: ...ic 30 100 4 95 2 50 25 0 5 48 5 Delicate 30 90 3 95 2 50 30 0 5 48 DRYER 10 15kg gas COIN OPERATED DRYING Cooling Motor Cycle number Cycle name Time Temperature Hysterisis Power Time Temperature Work...

Page 32: ...5 Quilted jackets 30 120 40 50 3 6 Windcheaters 20 130 40 46 5 the speed must always be calibrated manually depending on the effective load of laundry To have less mechanical action increase the numbe...

Page 33: ...ng for the multiple of time programmed means that the time must just be lengthened without the cooling phase in between every time For example in the case indicated above regarding 3 payments the heat...

Page 34: ...an be used for the successive cycle The maximum credit i e the maximum value that can be accumulated is 20 00 NOTE See also coin operation setting inthe previous paragraph In both cases it must be pos...

Page 35: ...ASPIRATION ANSCHLUSS ABASAUGUNGSMOTOR CONEXION MOTOR ASPIRACION 12000W 230 1 Schema di potenza collegamento 230 1 50 230 1 50 UK 230 3 50 60 400 3 50 60 440 3 60 K4 K4 K4 EBE10 EBE15 DRIVE K1 K1 1 2...

Page 36: ...oprocessor flash programming Plate2 LD1 LD2 LD3 LD4 LD5 To power board IN1 RL1 RL2 RL3 RL4 RL5 12CN3 11CN3 13CN3 15CN3 14CN3 14 15 12 13 26 0 16 Vac 1CN5A 4CN5A 57CN5A 6CN5A N N N L3 L3 T1 7 7A 4CN5A...

Page 37: ...M4 COIN OPERATION MICRO SWITCH M5 FILTER SAFETY DEVICE MICRO SWITCH PF1 CONTACT 1 MUSHROOM SHAPED BUTTON PF2 CONTACT 2 MUSHROOM SHAPED BUTTON Plate1 G400 CONTROL LOGIC BOARD Plate 2 POWER ACTUATOR BOA...

Page 38: ...38...

Page 39: ...E 10 6 2 DESCRIPTION OF THE PUSH BUTTON CONTROL PANEL 10 6 3 COMPLETE RANGE OF THE APPLICATIONS 10 6 4 INFORMATION REGARDING THE ELECTRIC PLANT 10 7 SPACE NECESSARY FOR THE INSTALLATION USE AND MAINTE...

Page 40: ...TEPPER 33 13 3 2 EXTERNAL COIN OPERATION OR WITH CENTRAL PAYMENT UNIT 33 13 3 3 ELECTONIC COIN OPERATION ON THE MACHINE 33 13 4 SET CYCLE COST 33 13 4 1 COIN OPERATION WITH STEPPER 33 13 4 2 EXTERNAL...

Page 41: ...CHILD PLACA DE CARACTER STICAS RIVENDITORE DISTRIBUTOR REVENDEUR VERTRIEB REVENDEDOR ASSISTENZA TECNICA AFTER SALES SERVICE SERVICE APRES VENTE KUNDENDIENST SERVICIO DE ASISTENCIA T CNICA MODELLO MODE...

Reviews: