1. l
oCatIon
To determine the safest and most efficient location for your
fireplace, the following guidelines should be taken into
consderaton.
Make sure the fireplace will fit. The size of your Kiva
Freplace wll vary wth each model Face Frame. Please
refer to
chart.a.-.wall.clearance.requirements.
and
figure 1 - Wall Clearance
.
The locaton of your Kva Freplace should not nterfere
wth ar condtonng ducts, wndows or doors, or be
affected by drafts,.
If possble, choose a locaton where the cuttng of josts
or roof rafters can be avoded.
Consder a locaton where the Ar Intake System Wall Vent
can be easly nstalled.
.
2.
.
.
inSTallaTion ConSiDeRaTionS
C
hart
a - W
all
C
learanCe
r
equIrementS
Frame Style:
Laguna Sandia
Hopi
Shalako
1 - Ceiling Radius Line
24”
24”
24”
24”
2 - Face Frame Clearance
36”
42”
42”
48”
3 - Floor Clearance Radius
54”
60”
60”
66”
4 - Banco Height
18”
18”
18”
18”
Figure 1 - Wall Clearance