22
USE AND CARE INSTRUCTIONS
NOTE about LP Gas Tank Exchange Programs
Many retailers that sell grills offer you the option of
replacing your empty LP Gas tank through an ex-
change service. Use only those reputable exchange
companies that inspect, precision fill, test and certify
their tanks. Exchange your tank only for an OPD safety
feature-equipped tank as described in the LP Gas tank
section of this manual.
Ÿ
How to Leak Test your LP Gas Tank
All leak tests must be repeated each time your LP
Gas tank is exchanged or refilled.
When checking for gas leaks do not smoke.
Do not use an open flame to check for gas leaks.
Your grill must be leak tested outdoors in a well-
ventilated area, away from ignition sources such as
gas fired or electrical appliances. During the leak test,
keep your grill away from open flames or sparks.
Do not use household cleaning agents. Damage to
gas assembly components can result.
Ÿ
Ÿ
Ÿ
For your safety:
Leak test new and exchanged LP Gas tanks BEFORE
connecting one to your grill.
Always keep new and exchanged LP Gas tanks in an
upright position during use, transit or storage.
LP Gas Model only:
Secure a 20 lb or 30 lb LP Gas Tank to
your Island
Turn your LP Gas Tank Valve clockwise to the
closed or OFF positon.
Unscrew the Wing Bolt from right bracket of tank
holder.
Place LP Gas tank into tank holder on the Tank
Tray.
Install the tank so the Tank Valve faces the rear
right corner of cabinet.
Align an additional nut and screw the Wing Bolt
into right bracket of tank holder to secure the gas
tank.
Type 1 connection per ANS
Z21.58-2007/CSA 1.6-2007
OUTDOOR COOKING GAS
APPLIANCES
LP Gas Model only:
Connect Regulator with Hose to your LPG Tank
Turn all Burner Valves to the OFF position.
Inspect the valve connection port and regulator
assembly for damage or debris. Remove any
debris. Never use damaged or plugged equip-
ment.
Connect the regulator assembly to the tank valve
and HAND TIGHTEN nut clockwise to a full stop.
DO NOT use a wrench to tighten because it could
damage the Quick Coupling Nut and result in a
hazardous condition.
Open the tank valve 1/4 to 1/2 (counterclockwise)
and use a soapy water solution to check all
connections for leaks before attempting to light
your grill. See
"Checking for LP Gas Leaks"
. If
a leak is found, turn the tank valve off and do not
use your grill until the leak is repaired.
One Nut is fixed to
Tank Holder. An
additional Nut and
Wing Bolt is secured
AFTER inserting tank
into tank hole.
Wing Bolt 1/4"x1/2"
Qty. 1
Part #
S233G04084
Additional Nut
CAUTION:
When the appliance is not in use the gas
must be turned off at the tank.
Place dust cap on cylinder valve outlet whenever the
cylinder is not in use. Only install the type of dust cap
on the cylinder valve outlet that is provided with the
cylinder valve. Other types of caps or plugs may result
in leakage of propane.
Brush soapy solution onto LP Gas tank in the
areas indicated by the arrows. See diagram.
If growing bubbles appear do not use or move the
LP Gas tank. Call an LP Gas Supplier or your Fire
Department.
Use a clean paintbrush and a 50/50 mild soap and
water solution.
If growing bubbles appear do not use or move
the LP Gas tank. Contact an LP Gas Supplier
or your Fire Department!
WARNING
!
!
Ÿ
Ÿ
Ÿ
Ÿ
Quick