background image

6

307622

Installation

Typical Installation

03815

C

D

R

P

B

K

A

N

G

E

F

H

J

L

M

Q

hydraulic outlet

7/8–14 UNF-2a

37

_

 (m) flare

hydraulic inlet
3/4–16 UNF-2a
37

_

 (m) flare

3/4 npt(f)

fluid intake

KEY
A
B
C
D
E

F
G
H
J
K

L
M
N
P
Q
R

Fluid hose to gun
Fluid drain valve
Suction hose
Hydraulic return line
Hydraulic supply line
shutoff valve

Pressure gauge
Flow control valve
Pressure reducing valve
Accumulator
Drain line

Hydraulic supply line
Hydraulic power supply
Ground wire
Wet-cup
Check valve
Hydraulic return line 
Shutoff valve

Summary of Contents for Viscount I 1000

Page 1: ...STAINLESS STEEL Viscountr I 1000 Pump 1000 psi 6 9 MPa 69 bar Maximum Hydraulic Input Pressure 1000 psi 6 9 MPa 69 bar Maximum Fluid Outlet Pressure Part No 218077 Series B U S Patent No 4 383 475 Pat...

Page 2: ...for its intended purpose If you are uncertain about usage call your Graco distributor D Do not alter or modify this equipment Use only genuine Graco parts and accessories D Check equipment daily Repai...

Page 3: ...igger safety operates before spraying D Lock the gun valve trigger safety when you stop spraying D Follow the Pressure Relief Procedure on page 8 whenever you are instructed to relieve pres sure stop...

Page 4: ...debris including solvent rags and gasoline D Electrically disconnect all equipment in the spray area D Extinguish all open flames or pilot lights in the spray area D Do not smoke in the spray area D...

Page 5: ...oses Use only electrically conductive hoses D Hydraulic power supply Follow manufacturer s recommendations D Spray gun or dispensing valve Obtain grounding through connection to a properly grounded fl...

Page 6: ...re 3 4 npt f fluid intake KEY A B C D E F G H J K L M N P Q R Fluid hose to gun Fluid drain valve Suction hose Hydraulic return line Hydraulic supply line shutoff valve Pressure gauge Flow control val...

Page 7: ...ly line and a minimum 5 8 in ID return line On the hydraulic oil supply line L install a shutoff valve E to isolate the system for servicing a fluid pressure gauge F to monitor hydraulic oil pressure...

Page 8: ...ydraulic supply line valve E first then the return line valve R 3 Unlock the gun valve trigger safety 4 Hold a metal part of the gun valve firmly to a grounded metal waste container and trigger it to...

Page 9: ...a grounded metal pail and aimed into it and use the lowest possible pressure to flush See Fig 2 Then follow the Pressure Relief Procedure on page 8 Fig 2 01136 Maintain firm metal to metal contact be...

Page 10: ...p empties the supply container air is sucked into the pump causing it to run too fast and to be damaged If the pump runs too fast shut it off immediately Fill the supply container and prime the pump t...

Page 11: ...tion Exhausted fluid supply Refill reprime or flush Held open or worn intake valve or piston packings Clear service Piston check valve needs adjustment Adjust See page 10 Excessive hydraulic fluid sup...

Page 12: ...s possible Relieve the pressure Stop the pump at the bottom of its stroke 2 Disconnect all hoses from the displacement pump 3 If you remove the pump from its mounting discon nect the hydraulic hoses f...

Page 13: ...107195 ADAPTER straight thd 37_ flare for 1 2 dia tube 1 9 217221 TUBE inlet 1 2 ID 1 10 107197 TEE run straight thd 3 4 16 UNF 2a 37_ flare m 1 11 104029 CLAMP grounding 1 12 104582 WASHER tab 1 13 1...

Page 14: ...t Pressure 1000 psi 6 9 MPa 69 bar Maximum Hydraulic Fluid Volume 3 gpm 11 7 liter min Fluid Delivery Rate at 60 cycles min 3 gpm 11 7 liter min Maximum Hydraulic Fluid Temperature 130_ F 54_ C Cycles...

Page 15: ...28 4 in 721 mm 13 7 in 348 mm 3 4 npt FLUID INLET 1 2 npt FLUID OUTLET 7 8 14 unf 2a 37_ flared m OUTLET ADAPTER 3 4 16 unf 2a 37_ flared m OUTLET ADAPTER 4 1 4 108 mm dia CUTOUT TWO 5 15 8 mm holes...

Page 16: ...h of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or propert...

Reviews: