background image

2

307622

Table of Contents

Warnings

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Installation

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Operation

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Maintenance

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Troubleshooting

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Service

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Parts

13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Technical Data

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Dimensions

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Mounting Hole Layout

15

. . . . . . . . . . . . . . . . . . . . . . . . . . 

Graco Standard Warranty

16

. . . . . . . . . . . . . . . . . . . . . . 

Graco Information

16

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Symbols

Warning Symbol

WARNING

This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.

Caution Symbol

CAUTION

This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
instructions.

WARNING

INSTRUCTIONS

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

D

This equipment is for professional use only.

D

Read all instruction manuals, tags, and labels before operating the equipment.

D

Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco
distributor.

D

Do not alter or modify this equipment. Use only genuine Graco parts and accessories.

D

Check equipment daily. Repair or replace worn or damaged parts immediately.

D

Do not exceed the maximum working pressure of the lowest rated system component. Refer to the

Technical Data

 on pages 14 for the maximum working pressure of this equipment.

D

Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the 

Tech-

nical Data

 section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

D

Do not use hoses to pull equipment.

D

Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose
Graco hoses to temperatures above 82

_

 C (180

_

 F) or below –40

_

 C (–40

_

 F).

D

Wear hearing protection when operating this equipment.

D

Do not lift pressurized equipment.

D

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

Summary of Contents for Viscount I 1000

Page 1: ...STAINLESS STEEL Viscountr I 1000 Pump 1000 psi 6 9 MPa 69 bar Maximum Hydraulic Input Pressure 1000 psi 6 9 MPa 69 bar Maximum Fluid Outlet Pressure Part No 218077 Series B U S Patent No 4 383 475 Pat...

Page 2: ...for its intended purpose If you are uncertain about usage call your Graco distributor D Do not alter or modify this equipment Use only genuine Graco parts and accessories D Check equipment daily Repai...

Page 3: ...igger safety operates before spraying D Lock the gun valve trigger safety when you stop spraying D Follow the Pressure Relief Procedure on page 8 whenever you are instructed to relieve pres sure stop...

Page 4: ...debris including solvent rags and gasoline D Electrically disconnect all equipment in the spray area D Extinguish all open flames or pilot lights in the spray area D Do not smoke in the spray area D...

Page 5: ...oses Use only electrically conductive hoses D Hydraulic power supply Follow manufacturer s recommendations D Spray gun or dispensing valve Obtain grounding through connection to a properly grounded fl...

Page 6: ...re 3 4 npt f fluid intake KEY A B C D E F G H J K L M N P Q R Fluid hose to gun Fluid drain valve Suction hose Hydraulic return line Hydraulic supply line shutoff valve Pressure gauge Flow control val...

Page 7: ...ly line and a minimum 5 8 in ID return line On the hydraulic oil supply line L install a shutoff valve E to isolate the system for servicing a fluid pressure gauge F to monitor hydraulic oil pressure...

Page 8: ...ydraulic supply line valve E first then the return line valve R 3 Unlock the gun valve trigger safety 4 Hold a metal part of the gun valve firmly to a grounded metal waste container and trigger it to...

Page 9: ...a grounded metal pail and aimed into it and use the lowest possible pressure to flush See Fig 2 Then follow the Pressure Relief Procedure on page 8 Fig 2 01136 Maintain firm metal to metal contact be...

Page 10: ...p empties the supply container air is sucked into the pump causing it to run too fast and to be damaged If the pump runs too fast shut it off immediately Fill the supply container and prime the pump t...

Page 11: ...tion Exhausted fluid supply Refill reprime or flush Held open or worn intake valve or piston packings Clear service Piston check valve needs adjustment Adjust See page 10 Excessive hydraulic fluid sup...

Page 12: ...s possible Relieve the pressure Stop the pump at the bottom of its stroke 2 Disconnect all hoses from the displacement pump 3 If you remove the pump from its mounting discon nect the hydraulic hoses f...

Page 13: ...107195 ADAPTER straight thd 37_ flare for 1 2 dia tube 1 9 217221 TUBE inlet 1 2 ID 1 10 107197 TEE run straight thd 3 4 16 UNF 2a 37_ flare m 1 11 104029 CLAMP grounding 1 12 104582 WASHER tab 1 13 1...

Page 14: ...t Pressure 1000 psi 6 9 MPa 69 bar Maximum Hydraulic Fluid Volume 3 gpm 11 7 liter min Fluid Delivery Rate at 60 cycles min 3 gpm 11 7 liter min Maximum Hydraulic Fluid Temperature 130_ F 54_ C Cycles...

Page 15: ...28 4 in 721 mm 13 7 in 348 mm 3 4 npt FLUID INLET 1 2 npt FLUID OUTLET 7 8 14 unf 2a 37_ flared m OUTLET ADAPTER 3 4 16 unf 2a 37_ flared m OUTLET ADAPTER 4 1 4 108 mm dia CUTOUT TWO 5 15 8 mm holes...

Page 16: ...h of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or propert...