Installation
Checking Resistance of Electrical
Components
WARNING
ELECTRIC SHOCK HAZARD
Do not open the electrical control panel,
unless you are a trained professional.
Before opening the control panel, make sure that
all power has been removed from the control panel.
You can check the resistance of the supply unit’s heat
sensors and heaters.
Sensor Resistance Checks
WARNING
ELECTROCUTION HAZARD
To reduce risk of injury or damage to
equipment, conduct these electrical
checks with the main disconnect OFF.
The supply unit includes heat sensors and controllers
for each of the heated zones. To check sensor resis-
tance:
1.
Make sure the power is off and that the disconnect
switch is in the OFF position.
2.
Make electrical resistance checks for the compo-
nents listed below. See the appropriate wiring
diagrams.
Model:
VAC:
Pages:
C32428
240
60 – 64
C32429
480
66 – 70
3.
Replace any parts whose resistance readings do
not comply with the ranges listed in the chart
below.
NOTE: Check resistance at ambient room tempera-
ture (63
_
– 77
_
F).
RTD Sensors
Zone
Component
Terminals
Value Range
1
Follower
1321 &
1331
97.4 – 102.8 ohms
2
Dispense
Hose 1
1521 &
1531
97.4 – 102.8 ohms
3
Dispense
Hose 2
1661 &
1671
97.4 – 102.8 ohms
4
Pump
1391 &
1401
97.4 – 102.8 ohms
5
Dispense
Gun 1
1591 &
1601
97.4 – 102.8 ohms
6
Dispense
Gun 2
1731 &
1741
97.4 – 102.8 ohms
Summary of Contents for Therm-O-Flow 55-H
Page 42: ...42 310 534 Notes ...
Page 60: ... 310 534 Electrical Control Panel and Wiring for C32428 240 VAC Lines 100 121 122 122 ...
Page 64: ...64 310 534 Electrical Control Panel and Wiring for C32428 240 VAC Lines 200 220 ...
Page 65: ...310 534 65 Notes ...
Page 66: ... 310 534 Electrical Control Panel and Wiring for C32429 480 VAC 122 122 Lines 100 121 ...
Page 70: ...70 310 534 Electrical Control Panel and Wiring for C32429 480 VAC Lines 200 220 ...