Service
Inspection Frequency
Ram
Periodically (once a month), inspect the ram guide
sleeves, rods and cylinders for wear or damage,
replace all worn parts. See the Service section of
Form# 310–533 for instructions on replacing worn
parts.
Pump
See the material pump’s instructions for its inspection
frequency.
Ground Fault Interrupt
Periodically (once a month) test the ground fault
interrupt switch by pushing the TEST button. See the
literature that came with the electrical control panel for
more information.
Hydraulic Power Supply
Once a month, check the hydraulic fluid level. Add
more fluid if necessary. See the Service section of
Form# 310–533 for instructions.