Maintenance
3A0294J
71
Maintenance
Preventive Maintenance
Schedule
The operating conditions of your particular system
determine how often maintenance is required. Establish
a preventive maintenance schedule by recording when
and what kind of maintenance is needed, and then
determine a regular schedule for checking your system.
Pump Maintenance
Wet Cup
Check the wet cup daily. Keep it 2/3 full with Graco
Throat Seal Liquid (TSL) or compatible solvent.
Corrosion Protection
Always flush the pump before the material dries on the
displacement rod. Never leave water or water-based
material in the pump overnight. First, flush with water or
a compatible solvent, then with mineral spirits solvent
(or white spirit). See
, page 52, for flushing
instructions. Relieve the pressure (see
62), but leave the mineral spirits in the pump to protect
the parts from corrosion.
Seals
Once a week, check and tighten throat seals on pump.
Be sure to follow the
ening seals.
Supply System Maintenance
Platen Maintenance
If the platen does not come out of the pail easily when
the pump is being raised, the air assist tube, or check
valve may be plugged. A plugged valve prevents air
from reaching the underside of the plate to assist in rais-
ing it from the pail. See the Supply Systems
Repair-Parts manual for instructions.
Adjust Spacers
Adjust spacers to be used with tapered pails if neces-
sary. See the Supply Systems Repair-Parts manual for
instructions.
Replace Wipers
To replace worn or damaged wipers, see the Supply
Systems Repair-Parts manual for instructions.
Cleaning Procedure
1.
Ensure all equipment is grounded. See
2.
Ensure the area where the system will be cleaned is
well ventilated; and remove all ignition sources.
3.
Relieve pressure. See
4.
Shutdown system and turn off all power. See
5.
Clean external surfaces only using a rag soaked in
solvent that is compatible with the dispense material
and the surfaces being cleaned.
6.
Clean the display with any alcohol-based household
cleaner, such as glass cleaner.
7.
Allow enough time for solvent to dry before using
system.
To reduce the risk of serious injury whenever you are
instructed to relieve pressure, always follow the
on page 51.
Summary of Contents for SmartWare 262370
Page 80: ...Parts 80 3A0294J Kit 262371 25 4 5 28 24 23 27 23 24 26 24 23 2 3c 24 23 3a 3b 30 32 33 31...
Page 84: ...Parts 84 3A0294J Kit 262373 continued 39 40 41 42 42 43 44 45 46 47 49 42 50 47 52 53 15...
Page 86: ...Parts 86 3A0294J Kit 262374 19 20 16 17 18 22 23 4 3a 5 2 24 25 27 29 28 32 3b 3c...
Page 87: ...Parts 3A0294J 87 Kit 262374 continued 33 34 35 36 36 37 38 39 40 41 43 36 44 43 46 47 13...
Page 92: ...Parts 92 3A0294J...