Pressure Relief Procedure
3A0294J
51
Pressure Relief Procedure
1.
Lock the gun/valve trigger.
2.
Change to manual mode in the run screen. See
3.
Shut off the air supply to the system.
4.
Shut off the air valve by pressing the Air On/Off soft
key on the display module.
5.
Close the manual air valve.
6.
Unlock the gun/valve trigger.
7.
Hold a metal part of the gun/valve firmly to the side
of a grounded metal pail, and press
or step
on the foot switch.
8.
Lock the gun/valve trigger.
9.
Open the material line drain valve and the pump
bleeder valve. Have a container ready to catch the
drainage.
10. Leave the pump bleeder valve open until you are
ready to spray/dispense again.
11. If you suspect that the spray tip/nozzle or hose is
completely clogged, or that pressure has not been
fully relieved after following the previous steps, very
slowly loosen the tip guard retaining nut hose end
coupling and relieve pressure gradually; then loosen
completely. Now clear the tip/nozzle or hose.
Trapped air can cause the pump to cycle
unexpectedly, which could result in serious injury
from splashing or moving parts
F
IG
. 102: Drain Material
Drain/Purge
+
Valve
Summary of Contents for SmartWare 262370
Page 80: ...Parts 80 3A0294J Kit 262371 25 4 5 28 24 23 27 23 24 26 24 23 2 3c 24 23 3a 3b 30 32 33 31...
Page 84: ...Parts 84 3A0294J Kit 262373 continued 39 40 41 42 42 43 44 45 46 47 49 42 50 47 52 53 15...
Page 86: ...Parts 86 3A0294J Kit 262374 19 20 16 17 18 22 23 4 3a 5 2 24 25 27 29 28 32 3b 3c...
Page 87: ...Parts 3A0294J 87 Kit 262374 continued 33 34 35 36 36 37 38 39 40 41 43 36 44 43 46 47 13...
Page 92: ...Parts 92 3A0294J...
Page 107: ...Technical Data 3A0294J 107...