Errors
3A0294J
69
Deviations
DF
Diving Up
Red Flash-
ing
Pump leaking during up stroke.
Replace worn piston valve or
packings.
DG
Diving Down
Red Flash-
ing
Pump leaking during down
stroke.
Replace worn intake valve or
priming rod seal.
Advisories
B2
Shot Volume
Less than Advi-
sory Setpoint
Yellow
Solid
Shot volume is less than the
advisory setpoint.
Increase the advisory setpoint on
Setup screen 11. Increase shot
consistency by decreasing
speed and valve shutoff time,
and increasing material
back-pressure.
B3
Shot Volume
Greater than
Advisory Set-
point
Yellow
Solid
Shot volume is greater than the
advisory setpoint.
Increase the advisory setpoint on
Setup screen 11. Increase shot
consistency by decreasing
speed and valve shutoff time,
and increasing material
back-pressure.
B9
Inconsistent
Shot
Yellow
Solid
A possible inconsistent shot
caused by a shot volume less
than overshoot.
Request a larger shot.
Verify that shot volume variation
is okay.
L2
Drum Low
Yellow
Solid
Drum low empty sensor has
tripped.
Replace empty drum with a full
drum.
MA
Maintenance
Counter
Yellow
Solid
Maintenance counter has
expired. Maintenance counter
has counted down to 0 from set-
point.
Volume specified by setpoint has
passed since last reset.
Code
Icon
Code Name
Light
Tower
Code
Cause
Solution
Summary of Contents for SmartWare 262370
Page 80: ...Parts 80 3A0294J Kit 262371 25 4 5 28 24 23 27 23 24 26 24 23 2 3c 24 23 3a 3b 30 32 33 31...
Page 84: ...Parts 84 3A0294J Kit 262373 continued 39 40 41 42 42 43 44 45 46 47 49 42 50 47 52 53 15...
Page 86: ...Parts 86 3A0294J Kit 262374 19 20 16 17 18 22 23 4 3a 5 2 24 25 27 29 28 32 3b 3c...
Page 87: ...Parts 3A0294J 87 Kit 262374 continued 33 34 35 36 36 37 38 39 40 41 43 36 44 43 46 47 13...
Page 92: ...Parts 92 3A0294J...
Page 107: ...Technical Data 3A0294J 107...