Set System Parameters
60
3A0294J
Calibrate
The actual weight/volume of material dispensed may
vary slightly from the displayed weight/volume. Use the
following procedure to calibrate the system as needed.
Calibration values can be set manually. However, it is
recommended to run the calibration procedure when
needed.
1.
Navigate to setup screen 10.
2.
Press
to start the overshoot calibration pro-
cess. The icons will display.
3.
Place a container that is at least as large as the
pump volume under the dispense valve.
4.
Hold down
or the foot switch to run the sys-
tem. The manual mode icon will flash. The pump will
go through the first changeover, stop to measure
the overshoot, then complete the second change-
over and stop.
5.
Release the start button or foot switch. The hour
glass icon is updated and the shot mode icon will
display.
6.
Remove any excess material from the dispense
valve, if necessary.
7.
Empty the container, if necessary. Set the scale to
zero.
8.
Press
to dispense a shot into the container.
When the shot completes the shot icon will disap-
pear and the first digit of the weight field will be high-
lighted.
Summary of Contents for SmartWare 262370
Page 80: ...Parts 80 3A0294J Kit 262371 25 4 5 28 24 23 27 23 24 26 24 23 2 3c 24 23 3a 3b 30 32 33 31...
Page 84: ...Parts 84 3A0294J Kit 262373 continued 39 40 41 42 42 43 44 45 46 47 49 42 50 47 52 53 15...
Page 86: ...Parts 86 3A0294J Kit 262374 19 20 16 17 18 22 23 4 3a 5 2 24 25 27 29 28 32 3b 3c...
Page 87: ...Parts 3A0294J 87 Kit 262374 continued 33 34 35 36 36 37 38 39 40 41 43 36 44 43 46 47 13...
Page 92: ...Parts 92 3A0294J...
Page 107: ...Technical Data 3A0294J 107...