Errors
68
3A0294J
Alarms (continued)
K1
Piston
Red Solid
Piston traveled less than one
inch in ten seconds.
Verify dispense valve is not stuck
closed.
Verify adequate air pressure to
machine.
L1
Drum Empty
Red Solid
Drum empty sensor tripped.
Replace empty drum with a full
drum.
P6
Pressure
Sensor
Red Solid
Pressure sensor is discon-
nected.
Reconnect pressure sensor.
Damaged pressure sensor wires. Replace pressure sensor.
WE
Dispense Valve Red Solid
Dispense valve is stuck open.
Check air solenoid wiring and air
connection. Replace or repair if
necessary.
Check dispense valve air con-
nection. Replace or repair if nec-
essary.
WJ
Air
Solenoid
Red Solid
Air solenoid is disconnected.
Plug in disconnected air sole-
noid.
Damaged air solenoid wires.
Replace air solenoid.
WK
Fluid
Solenoid
Red Solid
Fluid solenoid is disconnected.
Plug in disconnected fluid sole-
noid.
Damaged fluid solenoid wires.
Replace fluid solenoid.
WS
Invalid Pump
Red Solid
Invalid pump setup.
Select a valid pump in the Setup
screens.
Code
Icon
Code Name
Light
Tower
Code
Cause
Solution
Summary of Contents for SmartWare 262370
Page 80: ...Parts 80 3A0294J Kit 262371 25 4 5 28 24 23 27 23 24 26 24 23 2 3c 24 23 3a 3b 30 32 33 31...
Page 84: ...Parts 84 3A0294J Kit 262373 continued 39 40 41 42 42 43 44 45 46 47 49 42 50 47 52 53 15...
Page 86: ...Parts 86 3A0294J Kit 262374 19 20 16 17 18 22 23 4 3a 5 2 24 25 27 29 28 32 3b 3c...
Page 87: ...Parts 3A0294J 87 Kit 262374 continued 33 34 35 36 36 37 38 39 40 41 43 36 44 43 46 47 13...
Page 92: ...Parts 92 3A0294J...
Page 107: ...Technical Data 3A0294J 107...