Repair
Note
Use drop cloth or rags to protect Reactor
and surrounding areas from spills.
Note
Steps 14–16 applyto pump A. To
disconnect pump B, go to steps 17 and
18.
14. Disconnect fittings at fluid inlet (C) and outlet (D).
Also disconnect steel outlet tube from heater
inlet.
15. Disconnect tubes (T). Remove both tube fittings
(U) from wet-cup.
16. Loosen locknut (G) byhitting firmlywith a
non-sparking hammer. Unscrew pump far
enough to separate and push up finger guard
(P), to expose rod retaining pin. Push retaining
wire clip up. Push pin out. Continue unscrewing
pump.
Pump A
Figure 10
1
Flat side faces up.
2
Lubricate threads with ISO oil or grease.
3
Pump top threads must be nearly flush with
bearing face (N).
4
Finger guard (P) not used on E-30i model.
Note
Steps 17 and 18 applyto pump B.
17. Disconnect fluid inlet (C) and outlet (D). Also
disconnect steel outlet tube from heater inlet.
18. Push retaining wire clip (E) up. Push pin (F)
out. Loosen locknut (G) byhitting firmlywith a
non-sparking hammer. Unscrew pump.
Pump B
Figure 11
1
Flat side faces up.
2
Lubricate threads with ISO oil or grease.
3
Pump top threads must be nearly flush with
bearing face (N).
3A1706K
55
All manuals and user guides at all-guides.com
Summary of Contents for Reactor E-30i
Page 91: ...Notes Notes 3A1706K 91 All manuals and user guides at all guides com a l l g u i d e s c o m ...
Page 93: ...Parts 3A1706K 93 All manuals and user guides at all guides com ...
Page 94: ...Parts 94 3A1706K All manuals and user guides at all guides com ...
Page 102: ...Parts 102 3A1706K All manuals and user guides at all guides com ...
Page 105: ...Parts 3A1706K 105 All manuals and user guides at all guides com ...
Page 106: ...Parts 106 3A1706K All manuals and user guides at all guides com a l l g u i d e s c o m ...
Page 107: ...Parts 3A1706K 107 All manuals and user guides at all guides com ...
Page 118: ...Parts Air Control Panel 118 3A1706K All manuals and user guides at all guides com ...