Technical Speci
fi
cations
Technical Specifications
E-30i Models
U.S.
Metric
Maximum Fluid Working Pressure
Pressure
2000 psi
14 MPa, 140 bar
Maximum Fluid Temperature
E-30i
140°F
60°C
E-30i with booster heater
180°F
82°C
Maximum Output
Output
30 lb/min
13.5 kg/min
Maximum Heated Hose Length
Length
310 ft
94 m
Output per Cycle
A and B
0.0272 gal.
0.1034 liter
Operating Ambient Temperature Range
Temperature
20° to 120°F
-7° to 49°C
Auxiliary Power Available
Voltage
120 Vac or 240 Vac, 60 Hz
Engine
Model
Perkins 404–22G, 2.2 L, 29 HP
Alternator
Model
Mecc Alte 22 kW, 240 V, 1 PH, 60 Hz, pancake style
Battery Requirements
Voltage
12 Vdc
Minimum Cold Cranking Amps
800 CCA
Connection Type
Post Style
Recommended Battery Size
BC Group Number
34
Length
10.25 in.
260 mm
Width
6.81 in.
173 mm
Height
7.88 in.
200 mm
Booster Heater Power
E-30i
None
E-30i with booster heat
4000 Watts
154
3A1706K
All manuals and user guides at all-guides.com
Summary of Contents for Reactor E-30i
Page 91: ...Notes Notes 3A1706K 91 All manuals and user guides at all guides com a l l g u i d e s c o m ...
Page 93: ...Parts 3A1706K 93 All manuals and user guides at all guides com ...
Page 94: ...Parts 94 3A1706K All manuals and user guides at all guides com ...
Page 102: ...Parts 102 3A1706K All manuals and user guides at all guides com ...
Page 105: ...Parts 3A1706K 105 All manuals and user guides at all guides com ...
Page 106: ...Parts 106 3A1706K All manuals and user guides at all guides com a l l g u i d e s c o m ...
Page 107: ...Parts 3A1706K 107 All manuals and user guides at all guides com ...
Page 118: ...Parts Air Control Panel 118 3A1706K All manuals and user guides at all guides com ...