Repair
Install Pump
Note
Steps 1–5 applyto pump B. To reconnect
pump A, proceed to step 6.
1. Ensure locknut (G) is screwed on pump with flat
side up. Screw pump into bearing housing (M)
until pin holes align. Push pin (F) in. Pull retaining
wire clip (E) down. See
Fig. 11, page 54
for view
and assemblynotes.
2. Continue screwing pump into housing until fluid
outlet (D) is aligned with steel tube and top
threads are +/- 1/16 in. (2 mm) of bearing face
(N).
3. Tighten locknut (G) byhitting firmlywith a
non-sparking hammer.
4. Reconnect fluid inlet (C) and outlet (D).
5. Go to step 13.
Note
Steps 6–12 applyto pump A only.
6. Ensure star-shaped locknut (G) is screwed on
pump with flat side up. Carefullytwist and extend
displacement rod 2 in. (51 mm) above wet-cup.
See
Fig. 10, page 54
for view and assembly
notes.
7. Start threading pump into bearing housing
(M). Place finger guard (P) over rod when it is
accessible through window of bearing housing.
When pin holes align, insert pin. Pull retaining
wire clip down.
Note
Finger guard is not used on E-30i model.
8. Seat finger guard (P) on wet-cup. Continue
threading pump into bearing housing (M) until top
threads are +/- 1/16 in. (2 mm) of bearing face
(N). Ensure that barbed fittings at wet-cup flush
ports are accessible.
9. Connect component A outlet tube looselyat
pump and at heater. Line up tube, then tighten
fittings securely.
10. Tighten star-shaped locknut (G) byhitting firmly
with a non-sparking hammer.
11. Applythin film of TSL to barbed fittings. Using
two hands, support tubes (T) while pushing
straight onto barbed fittings. Do not let tubes
kink or buckle. Secure each tube with a wire tie
between two barbs.
12. Reconnect fluid inlet (C).
13. Purge air and prime the system. See Reactor
operation manual.
Repair Drive Housing
Removal
1. Press
to stop the pumps.
2. Turn off heat zones.
3. Flush pump.
4. Press
to park the Component A Pump.
5. Press
to deactivate the system.
6. Turn off the air compressor, air dryer, and
breathing air.
7. Close the main air shutoff valve.
8. Turn main power switch off.
To prevent electric shock do not remove any
shrouds or open the electrical enclosure door.
240 V is still present in the system until the
engine has stopped.
56
3A1706K
All manuals and user guides at all-guides.com
all-guides.com
Summary of Contents for Reactor E-30i
Page 91: ...Notes Notes 3A1706K 91 All manuals and user guides at all guides com a l l g u i d e s c o m ...
Page 93: ...Parts 3A1706K 93 All manuals and user guides at all guides com ...
Page 94: ...Parts 94 3A1706K All manuals and user guides at all guides com ...
Page 102: ...Parts 102 3A1706K All manuals and user guides at all guides com ...
Page 105: ...Parts 3A1706K 105 All manuals and user guides at all guides com ...
Page 106: ...Parts 106 3A1706K All manuals and user guides at all guides com a l l g u i d e s c o m ...
Page 107: ...Parts 3A1706K 107 All manuals and user guides at all guides com ...
Page 118: ...Parts Air Control Panel 118 3A1706K All manuals and user guides at all guides com ...