background image

11

307929

Installation

Converting to a Two-Gun System

To convert your sprayer to a two-gun system, refer to
the following applicable paragraph for your model
(refer to page 12 for Models 231162, 224629 and
231161). Order the parts listed, and perform the as-
sembly procedure.

Model 231158 (Refer to Figs. 6 and 7, and the Parts
Drawing on page 16)

WARNING

Before performing this procedure, follow the 

Pres-

sure Relief Procedure 

on page 14. Disconnect all

hoses from the pump.

NOTE: 

 Model 231158 includes a hose and gun set, so

you should order only one additional gun, air hose and
fluid hose.

Part No.

Description

Qty

156877

NIPPLE; 1/2 npt; 2.5” long

2

158683

ELBOW, 90

; 1/2 npt (m x f)

2

103475

TEE; 1/2 npt(f) run; 
1/2 npt(f) branch

1

104267

AIR REGULATOR

1

101180

GAUGE, pressure, air

1

100509

PLUG, pipe; 1/4 npt

1

166999

ELBOW, street, reducing;
1/2 npt(m) x 1/4 npt(f)

1

162453

NIPPLE; 1/4 npt x 1/4 npsm

2

100840

ELBOW, street, 90

1/4 npt (m x f)

1

238852

GUN, spray, air-assisted airless

2

216069

HOSE, air; nylon; 1/4” ID;
cpld 1/4 npsm (fbe) swivel;
26 ft (7.9 m) long

2

214698

HOSE, fluid; nylon; 3/16” ID;
cpld 1/4 npsm(f) swivel x
1/4 npt(m); 25 ft (7.6 m) long

2

1.

Remove the gun air regulator (31) from the nipple
(30) coming off the air manifold (29). Do not re-
move any parts from the regulator. Save the
regulator for use in step 4. See Fig. 6.

2.

Install a 101180 Gauge (P) and 100509 Plug (Q)
on a 104267 Air Regulator (R). Screw a 166999
Elbow (S) into the outlet port of this air regulator,
and screw a 162453 Nipple (T) into the elbow.

3.

Screw the branch of the 103475 Tee (L) onto the
nipple (30) at the air manifold (29). Install a
156877 Nipple (M) in each open port of the tee.
Screw a 158683 Elbow (N) onto each nipple.

4.

Install the air regulator removed in step 1 onto one
of the elbows (N). This is the air control for the first
gun. Install the air regulator assembled in step 2
onto the other elbow (N), so both regulators are
facing the same way. This is the air control for the
second gun.

5.

Remove the plug (27) from the optional outlet port
of the fluid filter (25). Install a 100840 Elbow (V)
and 162453 Nipple (T) in its place. See Detail A of
Fig. 7. This is the fluid connection for the second
gun.

6.

Connect the fluid and air hoses to the guns as
explained on page 6 (see Detail D of Fig. 7).

Summary of Contents for Ratio Monark Hydra-Spray Series

Page 1: ...ations Includes pump cart hose gun and tip Model 231162 Series B For cold spray applications Includes pump cart fluid regulation kit 222564 hose gun and tip Model 224629 Series A For heated spray appl...

Page 2: ...r Do not alter or modify this equipment Use only genuine Graco parts and accessories Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum working pressur...

Page 3: ...gun trigger safety operates before spraying Lock the gun trigger safety when you stop spraying Follow the Pressure Relief Procedure on page 14 whenever you are instructed to relieve pres sure stop sp...

Page 4: ...e of debris including solvent rags and gasoline Electrically disconnect all equipment in the spray area Extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do n...

Page 5: ...in the spray area Check your local electrical code for detailed grounding instructions for your area and type of equipment Be sure to ground all of this spray equipment 1 Pump loosen the grounding lug...

Page 6: ...cycle unexpectedly To bleed air from the pump the pump air regulator must be open when you close this valve The air relief valve 52 opens automatically to relieve air pressure to the pump if the the p...

Page 7: ...nnect the fluid regulator and bracket to the side of the cart 7 using the screw 66l lockwasher 66m and nut 66n Connect the 22 560 mm hose 66h to the outlet of the fluid filter 25 Connect the gun air s...

Page 8: ...all male threads except at swiveling connections 1 Remove the cover from the electrical box H at the back of the heater 67 Screw the bushing 74 into the inlet of the electrical box Install the cord g...

Page 9: ...ck valve points away from the pump Screw the rigid end of the adapter 71 onto the check valve See Fig 5 6 Install the 3 8 npt nipple 63 in the heater outlet Screw the male end of the 90 swivel 19 into...

Page 10: ...support bracket 4 Screw one of the nipples 41 into the outlet in the base of the back pressure regulator 83 then screw one of the elbows 40 onto the nipple so the male end of the elbow faces forward I...

Page 11: ...ivel 26 ft 7 9 m long 2 214698 HOSE fluid nylon 3 16 ID cpld 1 4 npsm f swivel x 1 4 npt m 25 ft 7 6 m long 2 1 Remove the gun air regulator 31 from the nipple 30 coming off the air manifold 29 Do not...

Page 12: ...e 14 Disconnect all hoses from the pump NOTE For Model 224629 order two 238852 Guns and two 222264 Hose Kits Model 231161 includes a gun and a hose kit so you should order only one additional gun and...

Page 13: ...els 224629 231161 Only V 40 25 66f 66a 66b 66b 66j 66e 66c 66d U T 83 T V 80 41 40 41 DETAIL D Assembly of Hoses and Gun Models 231158 and 231162 Only DETAIL E Assembly of Hose Kit and Gun Models 2246...

Page 14: ...warnings cautions and instructions in this manual and all manuals supplied with each compo nent or accessory Flush the Pump Before Using Pumps are tested with lightweight oil which is left in to prote...

Page 15: ...mp and lines with fluid being sure to eliminate all air from the fluid sys tem or flush the pump as described in Shutdown and Care at right Heated Systems Operating instructions for a heated circulati...

Page 16: ...16 307929 Parts 0979B Model 231158 1 3 4 5 7 21 22 23 20 25 27 27 29 30 31 32 33 33 REF 34 38 41 41 52 57 60 61 62 24 64 65 39 84 85 86 A A 7 REF See Detail Above For Parts 26 40 6...

Page 17: ...range See 308167 for parts 2 32 161037 UNION adapter 90 1 2 npt m x 3 8 npsm f swivel 1 33 204560 HOSE air buna N 3 8 ID cpld 3 8 npt mbe 18 457 mm long 1 34 101180 GAUGE pressure air 0 200 psi 0 14 b...

Page 18: ...25 27 27 29 30 31 32 33 33 REF 34 38 41 40 52 57 60 61 62 24 64 65 66a 66b 66c 66e 66d 66f 66h 66h REF Ref No 66 Fluid Regulation Kit includes items 66a 66q 39 A A B B 66j 66k 66l 66m 66n 66q 66p 66b...

Page 19: ...not shown 1 52 103347 VALVE relief air 1 57 171987 TEE 3 8 npt x 1 4 npt run 3 8 npt branch 1 60 222297 UNION adapter 45 1 2 npt m x 1 2 npsm f swivel 1 61 158491 NIPPLE 1 2 npt 1 5 8 long 1 62 107142...

Page 20: ...23 20 25 27 27 29 30 31 32 33 33 REF 34 38 41 41 52 57 60 61 62 64 65 39 84 86 A A B B 7 REF 38 78 77 79 80 REF 81 82 83 41 Part Of Item 67 87 88 89 90 91 92 Ref No 85 Hose Kit Includes Items 86 92 C...

Page 21: ...4 150286 ADAPTER 3 8 npt m x f 1 65 210658 DRAIN VALVE 3 8 npt mbe See 306861 for parts 1 67 220522 VISCON HEATER 120V See 307805 for parts 1 70 206962 CHECK VALVE 3 8 npt mbe 1 71 159801 UNION adapte...

Page 22: ...22 307929 Notes...

Page 23: ...t pipe sealant 110110 Kit 222436 includes some parts not required for this pump 156953 Mounting Stud 100639 Lockwashers 100023 Washer 100307 Nut and 102814 Gauge Manual Change Summary This manual was...

Page 24: ...y shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any oth...

Reviews: