Setup
12
309908G
Setup
3.
Tighten all fittings on unit.
WARNING
Do not install equipment approved only for non-haz-
ardous location in a hazardous area. Substitution of
components may impair intrinsic safety and cause per-
sonal injury. Read warnings, page 5. Ground equip-
ment as instructed below.
1.
Connect ProMix Easy ground wire (W) to a true
earth ground.
Non-intrinsically safe units must be hardwired or
supplied with a power cord (not included). See
page 8.
2.
Connect the fluid hose (S) to the fluid manifold out-
let. Do not install gun spray tip yet.
W
TI4792a
TI4793a
S
4.
Pump-based models only: Fill pumps A and B pack-
ing nuts with throat seal liquid (TSL).
5.
Connect air supply line (V) to air inlet.
Air supply requirement: 110 psi (0.8 MPa, 8 bar)
maximum, 70 psi (483 kPa, 4.8 bar) minimum.
Flow volume required: 20 scfm minimum; 125
scfm maximum.
V