Overview
309908G
7
Overview
Usage
The ProMix Easy can mix most two-component paints. It
is not for use with “quick-setting” paints (those with a pot
life of less than 5 minutes) without modification. Contact
your distributor for information.
The ProMix Easy is operated with the User Interface, Air
Controls and Fluid Controls, described below and on
page 10. Refer to F
IG
. 1 and F
User Interface
The User Interface has 6 main interfaces.
1.
Function Knob to select desired function:
2.
Start button
to initiate functions.
3.
Stop button
to terminate functions.
4.
Key switch to change ratio, pot life time, pot life vol-
ume, or calibration data.
5.
Display (five digits) to view:
•
Software revision level at startup
•
Ratio
•
Pot life time and reset volume
•
Alarm codes
•
Sensor calibration factor.
6.
Data port allows for connection to a PC serial port
to download volume totalizer, operation, ratio set-
ting, and error alarm data.
Icon
Function
Spray: proportion and spray material.
Run A: operate A independent of B (prim-
ing, flushing) for 12 cycles (500 cc with
meter).
Run B: operate B independent of A (prim-
ing, flushing) for 12 cycles (500 cc with
meter).
Batch Dispense: dispense proportioned
amounts of A and B (1 pint/500 cc).
Pump Test: dispense predetermined
amount of A and B to verify pump opera-
tion.
Recirculation: circulate fluid A and/or B up
to the mix manifold.
Pot Life Timer: display potlife time left.
Pressure Relief/Park: allows pressure relief
and runs pumps to the bottom of stroke.
See page 14.
•
System totalizers count in Spray and Batch
Dispense functions only.
•
A and B Indicators (LT) show which dispense
valve(s) is open.
WARNING
To avoid impairing intrinsic safety and reduce the risk
of fire and explosion, the PC must be in a non-hazard-
ous location and a safety barrier must be installed
between the PC and ProMix Easy unit. See ProMix
Easy data download kit manual 309623.
F
IG
. 1. User Interface
You must recalibrate the circuit board whenever the
main circuit board, software, or sensor is replaced,
or when Alarm 8 occurs. See Recalibrate
Pump-based System, page 29.
3
5
1
2
6
4
LT