Alarms
309908G
33
Operating Errors (con-
tinued)
22
High Ratio (units with
meter[s] only)
Spray
Mix ratio higher than
Tolerance
Flow rate too high
Slow actuation of dispense valve A or B
Clogged flow meter
23
Low Ratio (units with
meter[s] only)
Spray
Mix ratio lower than
Target - Tolerance
24
Dose Timeout A (units
with meter[s] only)
Spray
Air flow switch indicates
more than 40 sec of air
flow without dose com-
pleting
Air flow switch stuck open.
Atomizing air leak downstream of air flow switch.
Clogged flow meter.
Gun triggered without fluid (dusting parts)
25
Dose Timeout B (units
with meter[s] only)
26
Park Timeout
(pump-based units only)
Park
Pumps not at bottom of
stroke
Sampling valves closed, or gun not triggered.
Testing Error
15
Piston packing/ball A*
Test
Pump does not com-
pletely stall in up stroke
Piston packing or ball check failure
16
Piston packing/ball B*
17
Inlet Ball A*
Test
Pump does not com-
pletely stall in downstroke
Intake valve ball check failure
18
Inlet Ball B*
19
Dispense Valve A*
Test
Pump does not com-
pletely stall in both up
and down strokes
Throat packing or dispense valve failure
20
Dispense Valve B*
27
Pump Calibration
Timeout A
Run A
Pump doesn’t run
through calibration.
Sampling valves closed.
28
Pump Calibration
Timeout B
Run B
Code
Alarm
Active
Problem
Cause