Installation
8
309908G
Installation
The Typical Installation shown in F
. 3 is not an actual
system design. Contact your Graco distributor for assis-
tance in designing your system. Be sure all accessories
are adequately sized and pressure-rated to meet sys-
tem requirements.
Reference numbers and letters in the text refer to num-
bers and letters in the figures.
Icons in the text refer to icons on the User Interface.
Mounting
The ProMix Easy may be stand-mounted, cart-mounted,
or wall mounted. Stand and Caster Kits are available to
convert a wall-mount unit. Contact your Graco distribu-
tor.
1.
Ensure that the wall and mounting hardware are
strong enough to support the weight of the equip-
ment, fluid, hoses, and stress caused during opera-
tion.
2.
Using the equipment as a template, mark the
mounting holes on the wall at a convenient height
for the operator and so equipment is easily accessi-
ble for maintenance. Ensure that the equipment is
level. See Wall Mounting Diagram, page 39.
3.
Drill mounting holes in the wall. Install anchors as
needed.
4.
Bolt equipment securely to the wall.
Power Connection (non-IS units
only)
ProMix Easy non-IS units operate with 93-250 Vac,
50/60 Hz input power, with a maximum 1.2 amp current
draw. The power supply circuit must be protected with a
15 amp maximum circuit breaker. A switch or circuit
breaker must be must be installed close to the ProMix
Easy, within reach of the operator. The switch or circuit
breaker must be marked as the disconnecting device for
the ProMix Easy.
When the unit is first started up or has been
shutdown for longer than 2 months, you must turn it
on for 8 hours to recharge battery. Reset the date
and time with the Setup program, which is available
with the data download kit.
The unit should be run continuously for 8 hours or
more at least once per month to maintain proper
charge. If the battery is not recharged on a regular
schedule, the date information may be reset. If the
date is reset the date information will be incorrect in
the data log.
Non-intrinsically safe units must be hardwired or
supplied with a power cord (not included). Power
cord must be compatible to your local power con-
figuration. Wire gauge size must be 14 AWG.
Connect the power cord wires (L1, L2, GND) to
the terminal block (Y) in the pneumatic control
box, see F
. 2.
WARNING
Installing this equipment requires access to parts
which may cause electric shock or other serious injury
if work is not performed properly. Have a qualified
electrician connect power and ground to main power
switch terminals. Read warnings, page 5. Be sure your
installation complies with all National, State, and Local
safety and fire codes.
F
IG
. 2. Power Cord Connection (Non-IS Units Only)
TI4795a
GND
Y
L2
L1