Installation
6
3A1451C
Electronic Control Control (1) and Gasket
(2) Installation
Kits: 257350 and 257351
NOTE: It is important to properly seat gasket (2) when
installing electronic control (1) to fluid section. An
improperly seated gasket could cause the meter to
report invalid dispense amounts because the glass reed
switches are broken.
Connecting Hose to Meter
1.
Follow the Pressure Relief Procedure, page 4.
2.
Slide the swivel cover (34) onto the hose, small end
first, before connecting hose fitting to swivel (4) (F
IG
.
6).
3.
Apply thread sealant to the male threads of the hose
fitting. Thread the hose fitting into the swivel (4) and
tighten firmly (F
IG
. 6).
NOTE: Make sure you let sealant cure to the manufac-
turer’s recommendations before you let fluid into the
system.
Installing Extension and Nozzle on Meter
1.
Thread the fitting (26c) onto the extension (26a).
2.
Thread extension fitting (26c) into meter outlet at
least three full turns. (F
. 7).
3.
Thread new nozzle (26b) onto extension. With an
open-end, adjustable wrench.Tighten it firmly.
NOTE: Only tighten nozzle with the wrench on the flats
of the nozzle bushing.
Do not disassemble the bush-
ing from the nozzle.
Disassembly will affect the perfor-
mance of the nozzle.
F
IG
. 5
F
IG
. 6
2
1
4
hose
fitting
ti0269
34
F
IG
. 7
NOTICE
Do not use a twist/lock or manual shut-off nozzle. You
must use an automatic nozzle on the meter or the
meter could be damaged.
F
IG
. 8
26c
26a
26b
B
ti12081a