Installation
4
3A1451C
Mounting Bracket
Mounting bracket 196471 is available for resting dis-
pense valve on a console. See Fig. 2.
NOTE: Do not obstruct the dispense valve trigger and
do not set the unit down resting on its trigger or it might
not stop dispensing.
Pressure Relief Procedure
The equipment stays pressurized until pressure is man-
ually relieved. To reduce the risk of serious injury from
pressurized fluid, accidental spray from the dispense
valve, or splashing fluid, follow this Pressure Relief
Procedure when you:
•
are instructed to relieve pressure.
•
check, clean, or service any system equipment.
•
install or clean fluid nozzles or filter.
1.
Turn off the power supply to the pump.
2.
Trigger the dispense valve into a waste container to
relieve pressure.
3.
Open any bleed–type master air valves and fluid
drain valves in the system.
4.
Leave the drain valve open until you are ready to
pressurize the system.
Grounding
Proper grounding is an essential part of maintaining a
safe system. The movement of fluids through the dis-
pensing system generates static electricity. Static elec-
tricity can cause fumes to ignite, resulting in explosion
and fire. To reduce the risk of static sparking, ground all
system components per local and national electrical
codes. Refer to user manuals for pump and other sys-
tem components to ground the following:
•
Pump:
Follow manufacturer’s recommenda-
tions.
•
Air and Fluid hoses:
Use only grounded
hoses.
•
Air compressor:
Follow the manufacturer’s
recommendations.
•
Fluid supply container:
Follow the local code.
To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of valve
firmly to side of grounded metal pail, then trigger valve.