Performance Charts
Overmolded Diaphragms
Fluid Pressure
Approximate Cycles per Minute
PSI
(MPa, bar)
A
B
C
D
0
40
(151)
80
(303)
120
(454)
160
(606)
200
(757)
31
62
93
124
155
0
25
(0.17, 1.7)
50
(0.34, 3.4)
75
(0.52, 5.2)
100
(0.70, 7.0)
125
(0.86, 8.6)
Fluid Flow — gpm (lpm)
Operating Air Pressure
A
125 psi (0.86 MPa, 8.6 bar)
B
100 psi (0.7 MPa, 7.0 bar)
C
70 psi (0.48 MPa, 4.8 bar)
D
40 psi (0.28 MPa, 2.8 bar)
Air Consumption
Approximate Cycles per Minute
Howto Read the Charts
1. Locate fluid flow rate along
bottom of chart.
2. Follow vertical line up to
intersection with selected
operating air pressure
curve.
3. Follow left to scale to read
fluid outlet pressure (top
chart) or air consumption
(bottom chart)
scfm
(Nm
3
/min.)
A
B
C
D
31
62
93
124
155
0
35
(1.0)
70
(2.0)
105
(3.0)
140
(4.0)
175
(5.0)
0
40
(151)
80
(303)
120
(454)
160
(606)
200
(757)
Fluid Flow — gpm (lpm)
3A2578C
21
Summary of Contents for Husky 2200F