Performance Charts
Performance Charts
Bolt-through Diaphragms
Fluid Pressure
Approximate Cycles per Minute
PSI
(MPa, bar)
0
40
(151)
80
(303)
120
(454)
160
(606)
200
(757)
25
50
75
100
125
0
25
(0.17, 1.7)
50
(0.34, 3.4)
75
(0.52, 5.2)
100
(0.70, 7.0)
125
(0.86, 8.6)
A
B
C
D
Fluid Flow — gpm (lpm)
Operating Air Pressure
A
125 psi (0.86 MPa, 8.6 bar)
B
100 psi (0.7 MPa, 7.0 bar)
C
70 psi (0.48 MPa, 4.8 bar)
D
40 psi (0.28 MPa, 2.8 bar)
Air Consumption
Approximate Cycles per Minute
Howto Read the Charts
1. Locate fluid flow rate along
bottom of chart.
2. Follow vertical line up to
intersection with selected
operating air pressure
curve.
3. Follow left to scale to read
fluid outlet pressure (top
chart) or air consumption
(bottom chart)
scfm
(Nm
3
/min.)
0
35
(1.0)
70
(2.0)
105
(3.0)
140
(4.0)
175
(5.0)
A
B
C
D
0
40
(151)
80
(303)
120
(454)
160
(606)
200
(757)
25
50
75
100
125
Fluid Flow — gpm (lpm)
20
3A2578C