Operation

Calibrating the Meter

NOTE:  This unit has been calibrated at the factory to
dispense lubricating oils; it should not require
additional calibration during installation.  If this unit will
be used to dispense antifreeze, and accuracy must be
greater than plus or minus 2 percent, it is
recommended that you use a calibration factor of
7230.

You must ground yourself to a true earth ground
while calibrating the meter.  You must keep
yourself constantly grounded when you touch
any electronic components inside the cover of
the dispense valve.  To order a grounding wrist
strap, order Part No. 112–190.

 

This is the procedure for calibrating the meter and
setting whether the display counts up from zero or
down from the preset amount in Preset mode.

NOTE: All units count up from zero in Non-Preset
mode.

See Calculating the Calibration Factor on page 11
for instructions on assessing the accuracy of the meter
and calculating the proper calibration factor.

1.

Remove the six screws (21) (see the Parts
Drawing
 on page 17) that hold the two halves of
the cover together, and open the unit to gain
access to the Calibration button.

2.

Locate the calibration button inside the unit, as
shown in Fig. 5.

Calibration
button

Fig. 5

06186

3.

Press the Calibration button.

The calibration factor is shown on the display, as
shown at top right.

06044

06815

CAL

4.

Press the Calibration button again.

The first digit blinks, which indicates that you can
change it.

5.

Press any button on the keypad to advance the
blinking digit by one until the digit is set to the
desired amount.

6.

Press the Calibration button again.

The next digit blinks, which indicates that you can
change it.

7.

Repeat steps 5 and 6 until all the digits are set.

When all the digits are set, either UP On or
UPOFF is shown on the display.  In UP On mode,
the unit counts up from zero.  In UPOFF mode, the
unit counts down from the preset amount.

8.

Press any button on the keypad to toggle between
UP On mode and UPOFF mode.

9.

Press the Calibration button again.

The unit returns to Normal mode.

10. Press the Calibration button again.

After about 15 seconds, the unit makes an audible
beep to indicate that the changes have been
saved.

NOTE:  You can view the calibration factor at any time:
Press the Total button repeatedly to see the Total, the
R-Total, and the calibration factor.

Summary of Contents for EM 238-451

Page 1: ...ube with 90 Elbow Unit of Measurement Liters Model 238 454 75 Bend 3 8 in Rigid Tube Model 238 455 3 8 in Coupled Flexible Hose Model 238 456 15 Bend 3 8 in Gear Lube Tube with 90 Elbow These dispense...

Page 2: ...re of the lowest rated system component See the Technical Data on page 18 for the maximum working pressure of this component Use fluids and solvents that are compatible with the equipment wetted parts...

Page 3: ...ic shock while using this equipment stop dis pensing immediately Do not use the equipment until you identify and correct the problem Provide fresh air ventilation to avoid the buildup of flammable fum...

Page 4: ...ow 191 155 Valve bracket for mounting on console 191 156 Valve bracket for mounting on hose reel valve bracket 191 155 Fig 2 06228 PRESSURIZED EQUIPMENT HAZARD The equipment stays pressurized until pr...

Page 5: ...ons 7 Relieve the pressure To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 4 8 Loosen and disconnect the hose f...

Page 6: ...set typically before each dispense cycle TOTAL non resettable total Displayed to show the cumulative amount that the dispense valve has ever dispensed and it cannot be reset PRESET A user entered amou...

Page 7: ...press the Reset button the display scrolls to the next unit of measurement NOTE You do not need to change the calibration for the different units of measurement 5 Press the Auto button with your choi...

Page 8: ...ow until you unlock the trigger To unlock the trigger press on the smooth part of the trigger see above until you feel it click out of the locked position Then release the trigger Fluid flow stops Dis...

Page 9: ...hort beeps occur within a certain volume of the preset amount as follows QTS Unit beeps within 0 4 quarts of preset amount PTS Unit beeps within 0 5 pints of preset amount GAL or LITERS Unit beeps wit...

Page 10: ...ress the Reset button The unit returns to Normal mode and the Normal mode display is shown Error Codes If after a dispensing cycle you see an error code on the display as shown below see the Error Cod...

Page 11: ...r of 6832 therefore change 6815 to 6832 See Calibrating the Meter on page 12 for instructions on changing the calibration factor Metric Measurement Measuring in liters and 1 liter is dispensed Error i...

Page 12: ...together and open the unit to gain access to the Calibration button 2 Locate the calibration button inside the unit as shown in Fig 5 Calibration button Fig 5 06186 3 Press the Calibration button The...

Page 13: ...b 15 8 to 16 9 N m If the problem remains contact your Graco distributor for repair or replacement Oil drips from nozzle Dripless nozzle is damaged or obstructed Inspect the nozzle for damage or obstr...

Page 14: ...ue to 140 to 150 in lb 15 8 to 16 9 N m Valve Repair Kit See the Parts List on page 16 and the Parts Drawing on page 17 The parts with asterisks next to their reference numbers are available in the Va...

Page 15: ...le wrench on the flats of the nozzle tighten it firmly See the Parts Drawing on page 17 Do not use the old non drip nozzle Part No 203 655 or any other manual shut off nozzle on the EM5 extension You...

Page 16: ...87 NOZZLE ASSEMBLY For Models 238 453 238 456 includes 7a through 7d 1 7a 191 038 TUBE gear lube 15 bend 3 8 in 1 7b 238 371 NOZZLE oil dripless 1 7c 113 419 NUT seal 3 8 in 18 NPT 2 7d 155 699 ELBOW...

Page 17: ...0 in lb 15 8 to 16 9 N m 2 3 4 25 1 14 15 18 19 23 24 3 Apply lubricant when reassembling 3 3 3 3 3 3 3 3 2 06041 8 4 Site glass Part No 238 372 may be purchased separately 4 5 5 Street elbow 155 699...

Page 18: ...nitrile rubber Fluid compatibility lubricating oils antifreeze mixtures Meter valve assembly pressure loss At 1 5 gpm 5 7 lpm with 30 weight oil at 70 F 21 C 17 psi 1 17 bar Default settings for calib...

Page 19: ...Notes...

Page 20: ...e equipment will be returned to the original purchaser transportation prepaid If inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonabl...

Reviews: