Kits and Accessories
333586D
77
Kits and Accessories
Accessories are available from Graco. Make certain all
accessories are adequately sized and pressure-rated to
meet the system’s requirements.
System Kits and Accessories
Light Tower Kit, 255467
For D200s, D200, and D60 single supply systems.
See the E-Flo iQ Supply System Operation manual for
more information.
Low Level Sensor Kit, 25E447
To install the Low Level Sensor:
1. Turn the Disconnect Switch (AZ) OFF.
2. Disconnect cable from the empty level sensor (EL).
3. Mount the low level sensor (LL) on the mounting
bracket.
4. Connect the splitter cable (SP) to the previously
disconnected cable.
5. Connect the splitter cable (SP) lead labeled EMPTY
to the empty level sensor (EL).
6. Connect the splitter cable (SP) lead labeled LOW to
the low level sensor (LL).
7. Raise/lower the low level sensor (LL) to the desired
position to activate the sensor.
8. See the E-Flo iQ Supply System Operation manual
to set up the low level sensor.
200 Liter (55 Gallon) Platen Cover Kits,
255691
See the Platen Cover Kit manual for more information.
ADM Kit, 25R542
Enclosed Wet Cup Recirculation Kit
See the Enclosed Wetcup Recirculation Kit manual for
more information.
Heat Control Box, 25R454
See
Heat Control Box
on page 70 for parts.
Part
Description
Qty.
24E451
MODULE, gca, adm
1
18A921
TOKEN, gca, upgrade, E-Flo iQ
1
LL
EL
SP