Installation
24
333586D
Installation
The E-Flo iQ Dispense System is shipped in five to six
containers:
1. iQ Ram Supply Unit that includes the fully
assembled ram, electric driver, and pump.
2. iQ Dispense Valve
3. Hoses (shipped in one or two containers depending
on the number of hoses used)
4. Fittings
5. Cables and a pressure transducer
The E-Flo iQ Tandem Dispense System is shipped in
ten to eleven containers:
1. iQ Ram Supply Unit that includes the fully
assembled ram, electric driver, and pump.
2. Second iQ Ram Supply Unit that includes the fully
assembled ram, electric driver, and pump.
3. iQ Dispense Valve
4. Hoses (shipped in three or four containers
depending on the number of hoses used)
5. Fittings
6. Tandem fittings
7. Cables and a pressure transducer
8. Tandem Kit
NOTE:
Additional items including CGM and accessories
may be shipped in additional containers.
This section describes how to install and set up the
E-Flo iQ system and make all the necessary component
connections.
Location
Remove the iQ Ram Supply Unit from its crate. Attach a
lifting sling at the proper lift locations (see F
IG
. 3). Lift off
of the pallet using a crane or a forklift.
To properly locate and anchor the iQ Ram Supply Unit
(A), see
Dimensions
on page 91.
NOTE:
The lift ring on the Driver (AB) is only to be used
for replacing the Driver. Do not use it to lift the entire
system.
Position the Ram Assembly (AA) so the Driver (AB),
Power Junction Box Switch (AK) and/or Disconnect
Switch (AZ), Integrated Air Controls (AG), and ADM
(AF) are easily accessible. Ensure that there is enough
space overhead for the Ram Assembly to raise fully.
Use the holes in the Ram Assembly base as a guide
and drill holes for 1/2 in. (13 mm) anchors.
Ensure that the Ram Assembly base is level in all direc
-
tions. If necessary, level the base using metal shims.
Secure the base to the floor using 1/2 in. (13 mm)
anchors that are long enough to prevent the Ram
Assembly from tipping.
All electrical wiring must be done by a qualified elec
-
trician and comply with all local codes and regula
-
tions.
NOTICE
Always lift the iQ Ram Supply Unit at the proper lift
locations (see F
IG
. 3). Do
not
lift in any other way.
Failure to lift at the proper lift locations can result in
damage to the system.
Summary of Contents for E-Flo iQ Dispense System
Page 95: ...Wiring Diagrams 333586D 95 Wiring Diagrams ...
Page 96: ...Wiring Diagrams 96 333586D ...
Page 97: ...Wiring Diagrams 333586D 97 ...
Page 98: ...Wiring Diagrams 98 333586D ...
Page 99: ...Wiring Diagrams 333586D 99 ...