Check Resistance (Heated Systems)
36
333586D
Table 1: Sensors
Port
Zone
Component
RTD Range
(Ohms)
RTD Pin
Numbers
Heater Element
Resistance (Ohms)
Heater Pin
Numbers
1
1
Heated Hose
100
G, K
See hose manual
See hose manual
2
Heated Accessory 1
100
M, K
See accessory manual
See accessory
manual
2
3
Heated Hose
100
G, K
See hose manual
See hose manual
4
Heated Accessory 2
100
M, K
See accessory manual
See accessory
manual
3
5
Heated Hose
100
G, K
See hose manual
See hose manual
6
Heated Accessory 3
100
M, K
See accessory manual
See accessory
manual
4
7
Not Used
NA
NA
NA
NA
8
Pump
1000
M, K
37
C, D
5
9
5 gallon platen
100
M, K
80
C, D
55 gallon platen
1000
M, K
15
C, D (#1)
A, J (#2)