Installation

Grounding

Proper grounding is an essential part of maintaining a
safe system.

To reduce the risk of static sparking, ground the pump.
Check your local electrical code for detailed grounding
instructions for your area and type of equipment. Be
sure to ground all of this equipment:

1.

Pump: use a ground wire and clamp as shown
below.

2.

Air and fluid hoses: use only electrically conductive
hoses with a maximum 500 ft (150 m) combined
hose length to ensure grounding continuity.

3.

Air compressor: follow manufacturer’s recommen-
dations.

4.

Spray gun: grounding is obtained through connec-
tion to a properly grounded fluid hose and pump.

5.

Object being sprayed: follow your local code.

6.

Fluid supply container: follow your local code.

7.

All solvent pails used when flushing or relieving
pressure, always hold a metal part of the gun
firmly to the side of a grounded metal pail, then
trigger the gun.

To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of the
spray gun firmly to the side of a grounded metal
pail, then trigger the spray gun.

To ground the pump:

To ground the pump, loosen the grounding lug locknut
(W) and washer (X). Insert one end of a 12 ga (1.5
mm

2

) minimum ground wire (Y) into the slot in lug (Z)

and tighten the locknut securely.  Connect the other
end of the wire to a true earth ground. Order Part No.
237–569, Ground Wire and Clamp.

Fig. 1

X

W

Y

Z

04111

Summary of Contents for Bulldog 221-104

Page 1: ...isplacement Pumps have an abrasion and corrosion resistant displacement rod and sleeve Refer to the Technical Data in the separate displacement pump manual 308 043 for wetted parts information INSTRUC...

Page 2: ...t sure call your Graco distributor D Do not alter or modify this equipment Use only genuine Graco parts and accessories D Check equipment daily Repair or replace worn or damaged parts immediately D Do...

Page 3: ...extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do not turn on or off any light switch in the spray area while operating or if fumes are present Do not oper...

Page 4: ...properly grounded fluid hose and pump 5 Object being sprayed follow your local code 6 Fluid supply container follow your local code 7 All solvent pails used when flushing or relieving pressure always...

Page 5: ...e adjusting or repairing the pump The Fluid Drain Valve helps relieve fluid pressure in the displacement pump hose and gun dispensing valve when shutting off the pump Triggering the gun dispensing val...

Page 6: ...very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually Clear the tip or hose obstruction Check Valve Adjustment The fluid piston and intake valve are facto...

Page 7: ...pump overnight If you are pumping water base fluid flush with water first then with a rust inhibitor such as mineral spirits Relieve the pressure but leave the rust inhibitor in the pump to protect th...

Page 8: ...ressure the pump will not oper ate below 30 psi 2 1 bar 210 KPa air pressure Fluid hose or gun is clogged Clean the hose or gun flush frequently Fluid is too heavy for the pump to prime Use an inducto...

Page 9: ...s out of the air motor as the pump is detached Reassembly See page 10 1 If removed screw the three tie rods 6 into the motor 11 2 If removed screw the bushing 59 into the outlet of the displacement pu...

Page 10: ...insert 3 4 101 936 NUT hex jam 3 4 10 1 5 158 674 O RING nitrile ribber 1 6 161 541 ROD tie 13 5 343 mm long 3 7 161 543 COUPLING connecting rod 1 8 161 544 NUT coupling 1 9 164 444 ROD connecting 7...

Page 11: ...si 35 bar 3 5 MPa at a maximum 100 psi 7 bar 700 KPa air input Air consumption 5 3 CFM 0 15 m at 1 gallon 3 78 l at 100 psi 7 bar 700 KPa air input Cycles per gallon liter 3 3 0 87 Maximum recommended...

Page 12: ...ll be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or prop erty or any other i...

Reviews: