2. Brooklyn II card is Dante clock slave. adc clocksource is "word" or "word 75Ω", ADC is clocked from Ex-
ternal Word Clock. Note: In this mode the external WC IN must be synchronous with the Dante Net-
work Clock. If the external WC is not synchronous with the Dante clock then the Brooklyn II might
mute the audio. If the two clocks are close in frequency but not synchronous, corrupt audio data will
be transmitted - (ticking, or dropped samples).
S1
ETH
BROOKLYN II
ETH
WC OUT
WC IN
m108 Dante
Interface
INTERNAL
CLOCK
ADC/DAC
CLOCK
IN
WC IN
WC OUT
S2
S3
s-LOCK PLL
3. Brooklyn II is Dante clock master. Dante ext. sync is "internal" adc clocksource is "internal", m108 is
System Master using Internal Clock. Note: Check boxes “Preferred Master” and “Enable Sync To Exter-
nal” for this m108 in the Dante Controller Clock Status Window.
m108 Owner's Manual
page 32
S1
ETH
BROOKLYN II
ETH
WC OUT
WC IN
m108 Dante
Interface
INTERNAL
CLOCK
ADC/DAC
CLOCK
IN
WC IN
WC OUT
S2
S3
s-LOCK PLL