Please secure minimum clearance as shown in the picture for adequate
ventilation and technical service.
Ventilation space in front of EK-Series displays must be furnished for heat
dispersion. If the area in front of EK-series displays must be sealed, there
must be consideration for the heat dispersion on the rear side of EK-series to
compensate.
During installation, do not apply pressure to any surface of
the panel. Damage to the panel may result from external pressure
or even minor impact to the panel. Physical and cosmetic damage
to displays is not covered under warranty.
6
Installation Precautions
3.
9”
[
100m
m
]
3.9” [100mm]
3.
9”
[
100m
m
]
3.9” [100mm]
Ventilation space must not be covered or closed off at the front of the
opening. If for some reason the opening needs to be covered, other means
of ventilation will need to be incorporated into the design. Contact GPO
Display for design review and recommendations.
Dimensions below are minimum required for proper ventilation
Please ensure alignment on the Z-axis for a level plane across
adjacent panels (as shown in the diagram below). If precautions are
not heeded, GPO Display will not accept responsibility for any
Failure due to such installation errors.
Bottom of product: When resting panel on any surface
(padded table, floor), do not tilt panel forwards as shown in
the diagram below. The weight of the display applied in an
uneven manner can result in damage.
X
X
Do not cover fan ventilation holes
Carefully install EK-series displays so as not to cover the fan air holes with any structural object.
If the holes are covered with anything, the inner temperature can be raised rapidly and it can cause malfunction.