www.gpodisplay.com
♦
Remote Control Lock On/Off
♦
Source Change
STX
R/W
ID
CON
CMD
Value
0xF5
0x88
0x00 – 0x63
0xFE
0x36
0xXX
o
CMD: 0x36 for command of Remote Control Lock
o
Value: 0x00 for OFF
0x01 for ON
o
CMD: 0x01 for command of Video Input Source
o
Value: 0x01 for Display Port
0x02 for HDMI
♦
Temperature Reading
o
CMD: 0x3C for Current Temperature Reading
o
Value = Actual Temperature (by Celsius) x 2 + 60
Ex) If reading value is 122 (0x7A),
Actual Temperature = (122 – 60) / 2 = 31
°
C
♦
MFC Setting ( Motion Flow Compensation )
o
CMD: 0x6A for MFC Setting ( Motion Flow Compensation )
o
Value: 0x00 ( OFF ), 0x01 ( LOW ), 0x02 ( MIDDLE ), 0x03 ( HIGH )
♦
Temperature Shutdown Setting
o
CMD: 0x48 for Shutdown Temperature setting
o
Value = desired shutdown temperature (by Celsius) x 2 + 60
Ex) If desired shutdown temperature is 60
°
C,
Setting Value = 60 x 2 + 60 = 180 (0xB4)
STX
R/W
ID
CON
CMD
Value
0xF5
0x88
0x00 – 0x63
0xFE
0x01
0xXX
STX
R/W
ID
CON
CMD
0xF4
0x89
0x00 – 0x63
0xFC
0x3C
STX
R/W
ID
CON
CMD
Value
0xF5
0x88
0x00 – 0x63
0xFE
0x48
0xXX
STX
R/W
ID
CON
CMD
Value
0xF5
0x88
0x00 – 0x63
0xFE
0x6A
0xXX