7.2 Video wall Settings (Multi Vision)
♦
Horizontal Set Max Count
CMD: 0x44 for X max
Value: 0x01 – 0x0B ( 1 – 11)
♦
Vertical Set Max Count
Param: 0x45 for Y max
Value: 0x01 – 0x0B ( 1 – 11
)
♦
Horizontal Set Position
CMD: 0x42 for X Position
Value: 0x01 – 0x0B ( 1 – 11
)
♦
Vertical Set Position
CMD: 0x43 for Y Position
Value: 0x01 – 0x0B ( 1 – 11)
♦
Write Set ID Number
* Attention : Write Set ID Function must be only one connect Monitor (1 pc : 1 monitor)
ID : SET ID Number (Set ID 0~99)
0x01 ( Set ID# 1 ), 0x02 ( Set ID# 2), 0x0C ( Set ID# 12 ), 0x10 ( Set ID# 16 )R/W: 0xFE (Set Parameter Value)
CMD: 0x2A for SETID
Value: 0x00 – 0x63 (0 – 99)
STX
R/W
ID
CON
CMD
Value
0xF5
0x88
0x00 – 0x63
0xFE
0x2A
0xXX
STX
R/W
ID
CON
CMD
Value
0xF5
0x88
0x00 – 0x63
0xFE
0x44
0xXX
STX
R/W
ID
CON
CMD
Value
0xF5
0x88
0x00 – 0x63
0xFE
0x45
0xXX
STX
R/W
ID
CON
CMD
Value
0xF5
0x88
0x00 – 0x63
0xFE
0x42
0xXX
STX
R/W
ID
CON
CMD
Value
0xF5
0x88
0x00 – 0x63
0xFE
0x43
0xXX