GOW-MAC Instrument Co.
64
Series 580 Filament Replacement Chart
Part No.
Description
13-580-QD
WX fi laments
NOTE: Filaments are supplied in QUADS.
13-581-QD
AuW fi laments
A QUAD consists of 4 matched
13-582-QD
Ni fi laments
elements mounted in an aluminum
13-583-QD
WX7 fi laments
block for safe shipping. Each QUAD
13-585-QD
W2 fi laments
includes 4 new tube nuts.
13-586-QD
W2X fi laments
13-587-QD
Ni2 fi laments
13-584-18
8k Thermistors
NOTE: Sold in pairs
Series 580 Detector Replacement Chart
Detector
Option
Detector
Number
Part No.
Description
Filaments
200
10-580-00-2
TC cell, s.s. standard w/ 1/8” fi ttings (10-077)
WX
201
10-580-01-1
TC cell, s.s. standard w/ 1/8” fi ttings (10-077)
AuW
202
10-580-02-1
TC cell, s.s. standard w/ 1/8” fi ttings (10-077)
Ni
203
10-580-03-1
TC cell, s.s. standard w/ 1/8” fi ttings (10-077)
WX7
207
10-580-07-1
TC cell, s.s. standard w/ 1/8” fi ttings (10-077)
W2X
224
10-580-24-2
TC cell, s.s. standard w/ 1/8” fi ttings (10-077)
Ni2
204
10-580-04-1
TC cell, s.s. capillary w/ 1/8” fi ttings (10-955)
*WX7
205
10-580-05-2
TC cell, s.s. prep w/ 1/8” fi ttings (10-077)
WX
206
10-580-06-1
TC cell, s.s. prep w/ 1/8” fi ttings (10-077)
AuW
207
10-580-08-1
TC cell, s.s. prep w/ 1/8” fi ttings (10-077)
Ni
209
10-580-09-1
TC cell, s.s. nanokatharometer w/ 1/8” fi ttings (10-952)
*WX
210
10-580-10-1
TC cell, s.s. nanokatharometer w/ 1/8” fi ttings (10-952)
*AuW
211
10-580-11-1
TC cell, s.s. nanokatharometer w/ 1/8” fi ttings (10-952)
*Ni
212
10-580-12-1
TC cell, s.s. nanokatharometer w/ 1/8” fi ttings (10-952)
*WX7
213
10-580-13-2
TC cell, s.s. thermistor (10-133 type)
8k
214
10-580-14-1
TC Cell, s.s. GADE
W2
218
10-580-18-4
TC cell, wide bore capillary w/ 1/8” & 1/16” fi ttings (10-952)
*WX
219
10-580-19-1
TC cell, wide bore capillary w/ 1/8” & 1/16” fi ttings (10-952)
*AuW
220
10-580-20-1
TC cell, wide bore capillary w/ 1/8” & 1/16” fi ttings (10-952)
*Ni
221
10-580-21-1
TC cell, wide bore capillary w/ 1/8” & 1/16” fi ttings (10-952)
*WX7
225
10-580-25-1
TC cell, s.s. dual carrier w/ 1/8” fi ttings (10-801)
*W2B
227
10-580-27-1
TC cell, s.s. dual carrier w/ 1/8” fi ttings (10-801)
*WXB
*NOTE:
THESE FILAMENTS ARE NOT FIELD REPLACEABLE. DETECTOR MUST BE SENT
TO GOW-MAC FOR REPAIR.
Summary of Contents for 580 series
Page 2: ...GOW MAC Instrument Co 2 ...
Page 6: ...GOW MAC Instrument Co 6 ...
Page 8: ...GOW MAC Instrument Co 8 ...
Page 10: ...GOW MAC Instrument Co 10 ...
Page 24: ...GOW MAC Instrument Co 24 ...
Page 36: ...GOW MAC Instrument Co 36 ...
Page 42: ...GOW MAC Instrument Co 42 ...
Page 54: ...GOW MAC Instrument Co 54 ...
Page 62: ...GOW MAC Instrument Co 62 ...
Page 66: ...GOW MAC Instrument Co 66 ...
Page 68: ...GOW MAC Instrument Co 68 ...