58
GMC-I Messtechnik GmbH
10
Table of Operating and Query Commands
10.1
Adjustable Functions and Parameters
Setting
Command
Parameter
Meaning
Value Range / Selection
De
fa
ul
t
Set
tin
g A
fte
r
RE
SET
*RS
T
Manual
Re
m
o
te
Display and Interface Settings
1)
(see chapter 6, main menu level SETUP DISPLAY & INTERFACE)
Addr
n
Set device address for IEEE 488 (interface
configuration)
0
n
30
unv
X
bAUd
txt
RS 232
transmission speed
Set via menu selection, default setting: 9600 baud.
The following values can be selected manually:
1200, 1800, 2400, 3600, 4800, 7200, 9600, 14,400, 19,200,
28,800, 38,400, 57,600 or 115,200 [baud]
unv
X
DB
RS 232
data bits
7 or 8, set via selection menu, default setting: 8
unv
X
PB
RS 232
parity bit
Set via menu selection, default setting: none
The following values can be selected manually: nonE, EVEn or odd
unv
X
SB
RS 232
stop bit
1 or 2, Default setting: 1
unv
X
bAUd
txt
USB
transmission speed
(DB = 8, PB = no, SB = 1)
Set via menu selection, default setting: 115,200 baud.
The following values can be selected manually:
9600, 14,400, 19,200, 28,800, 38,400, 57,600 or 115200 [baud]
unv
X
DDC
n
Display switching time
Set via menu selection, default setting: 10 s. The following values
can be selected manually: 5, 10, 15, 20, 30, 45, 90 or 180 [s]
unv
X
General Commands and Settings
*CLS
Clear Status
—
X
*DDT
txt
Define Device Trigger
txt Command string with up to 80 characters,
delimiter for commands is slash (/) instead of semicolon (;)
—
X
*ESE
n
Standard Event Status Enable
0
n
255, n = decimal equivalent of register content
—
X
*OPC
Operation Complete
—
X
*PRE
n
Parallel Poll Enable Register Enable
0
n
255, n = decimal equivalent of register content
—
X
*PSC
n
Power-On Status Clear
n = 0, 1
—
X
*RCL
n
Recall a device setting stored to a setup memory
location (1 through 12/15)
1
n
12/15*;
Special case n = 99 means undo after *RST, *RCL #
—
X
X
*RST
Reset device to default values
Default
X
X
*SAV
n
Save current device settings to a setup memory lo-
cation (1 through 12/15)
1
n
12/15*
—
X
X
*SRE
n
Service Request Enable
0
n
255, n = decimal equivalent of register content
—
X
*TRG
Trigger for executing *DDT functions
—
X
*WAI
Wait to continue
—
X
DCL / SDC
Device clear function
—
X
ERAE
n
Device Dependent Event Register A Enable
0
n
255, n = decimal equivalent of register content
—
X
ERBE
n
Device Dependent Event Register B Enable
0
n
255, n = decimal equivalent of register content
—
X
ERCE
n
Device Dependent Event Register C Enable
0
n
255, n = decimal equivalent of register content
—
X
* /15 or /1700, respectively as from firmware version 004