45
Gossen Metrawatt GmbH
METRACELL BT PRO
10.9
Interval U Measurement
The
INTERVAL U
measuring function is used to measure voltage at any desired time intervals (voltage curve / capacity test of the entire bat-
tery). The shortest selectable time interval is 1 second. Measurement is continued at the specified time interval until ended by the user.
Se-
quence
Description of the Measurement
Display
1
Plug the alligator clips (
28) onto the multimeter test probe measurement cables and con-
nect them to the P–/COM and S+ sockets with the matching colors (
2
Connect the alligator clips to the battery’s power output:
red to plus, black to minus.
3
Press and hold the
FUNCTION
key for about 2 seconds in order to switch the battery tester on.
BTpro
<date>
<version>
<time>
4
Press any key to open the
main menu
.
If you’re already in another menu, press the
FUNCTION
key repeatedly until the
main menu
ap-
pears.
->
MEASUREMENT
DATA
5
Press the
OK
key in order to open the
MEASUREMENTS
menu.
The
MEASUREMENTS
menu is displayed.
->
MULTIMETER
FLOAT
6
Select
INTERVALL U
using the
▼ ▲
keys.
CONNECTOR
->
INTERVAL U
7
Press the
OK
key in order to open the selected menu for the measuring function.
->
START
SELECT.BATT
8
Before starting the measurement, the location, battery and limit value parameters must be set.
These can be:
–
Selected in the battery database via RFID
step 8a
–
Selected manually in the battery database
step 8b
–
Entered manually at the battery tester
step 8c
START
->
SELECT.BATT
8a
A battery database has been created
The battery database has been transferred to the battery tester
You use RFID technology for your system.
The DUTs in the battery database are linked to the corresponding RFID tags
1. Select
SELECT.BATT
with the
▼
key.
2. Press the
OK
key
The battery database is displayed. An acoustic signal indicates that the RFID reader is
ready.
3. Read the RFID tag (
An acoustic signal confirms reading and the DUT is displayed.
4. Press the
OK
key.
The battery is selected. The battery tester returns to the
MEASUREMENTS
menu.
START
->
SELECT.BATT
8b
A battery database has been created
The battery database has been transferred to the battery tester
1. Select
SELECT.BATT
with the
▼
key.
2. Press the
OK
key
The battery database is displayed. An acoustic signal indicates that the RFID reader is
ready.
3. Select a battery using the
▼ ▲
keys.
4. Press the
OK
key.
The battery is selected and the battery tester returns to the
MEASUREMENTS menu
.
START
->
SELECT.BATT
8c
1. Select the
AREA:XXXX.
parameter with the
▼
key.
2. Press the
OK
key.
The entry mode is active.
3. Enter the parameter’s first digit
4. Acknowledge your entry with the
OK
key.
5. Repeat steps 1 through 4 for all other parameter digits for battery number, interval and
upper and lower voltage limit values.
SELECT.BATT
->
AREA
:
0
000
9
Return to
START
using the
▲
key.
->
START
SELECT.BATT
10
Press the
OK
key in order to start the measurement.
COUNT:
- - - - - - -
XXXXXX
TIME:
XX:XX:XX