42
METRACELL BT PRO
Gossen Metrawatt GmbH
9
Press the
OK
key in order to start the measurement.
BLOCK
- - - - - - -
XXXX/X
AN:XXXX
BN:XXXX
10
Aim the IR temperature sensor at a suitable measuring point (e.g. minus pole) on the block.
Note
Observe the information on the size of the measuring point and on the distance from the
measuring point on the back of the accessory and in the associated operating instruc-
tions.
11
Press and hold the measurement activation key on the sensor.
12
Wait until a stable measured value is displayed.
13
Acknowledge the measured value at the battery tester by pressing the
OK
key.
14
Repeat the previously described measuring procedure for further battery blocks.
The measurement is ended automatically after all blocks have been completely measured. The
measured values are saved.
The measured value evaluation appears at the display
Example:
BLOCK
21.8 C
0004/2
AN:0001
BN:0010
15
Press the
OK
key repeatedly in order to view the evaluation (scroll), and to subsequently return
the display to the
TEMPERATURE
measurement.
NUMBER:
[XXXX]
AVER.:
XX.XXXX C