40
METRACELL BT PRO
Gossen Metrawatt GmbH
7b
A battery database has been created
18.
The battery database has been transferred to the battery tester
1. Select
SELECT.BATT
with the
▼
key.
2. Press the
OK
key
The battery database is displayed. An acoustic signal indicates that the RFID reader is
ready.
3. Select a battery using the
▼ ▲
keys.
4. Press the
OK
key.
The battery is selected and the battery tester returns to the
MEASUREMENTS menu
.
START
->
SELECT.BATT
7c
1. Select the
AREA:XXXX.
parameter with the
▼
key.
2. Press the
OK
key.
The entry mode is active.
3. Enter the parameter’s first digit
4. Acknowledge your entry with the
OK
key.
5. Repeat steps 1 through 4 for all other parameter digits for battery number, number of
blocks and upper and lower voltage limit values.
SELECT.BATT
->
AREA
:
0
000
8
Return to
START
using the
▲
key.
->
START
SELECT.BATT
9
Press the
OK
key in order to start the measurement.
BLOCK ----------------------
XXXX/X ----------------------
R(el) =
----------------------
R(ct) =
----------------------
10
Wait for the acoustic signal which is generated when no voltage is applied to the test probes.
Example:
BLOCK
12.2500V
0010/4
R(el) =
23.00 m
R(ct) =
12.00 m
11
Contact the battery poles: using suitable pressure, press the test probes against the poles.
12
Wait for the acoustic signal which indicates that the measured value is stable.
The measurement is hereby confirmed.
13
Remove the probes after hearing the acoustic signal.
14
Wait for the acoustic signal once again, which indicates that the test probes are again voltage-
free.
15
Repeat the previously described measuring procedure for further battery blocks.
The measurement is ended automatically after all blocks have been completely measured. The
measured values are saved.
The measured value evaluation appears at the display
16
Press the
OK
key repeatedly in order to view the evaluation (scroll), and to subsequently return
the display to the
RESISTANCE
measurement.
SUM:
[XXXX]
XX.XXV
AVER.:
+XX.XXXXV