78
MDE-LEDI-1099V4.0
Trap Name
Condition of execution
ntpStarting
The NTP client has restarted. It generally occurs if the product reboots
or if the NTP settings are modified..
newNTPSerSelected
The NTP client has selected a new NTP server to synchronize to. It is
sent during the first synchronization occuring after a reboot, if the NTP
client selects a new NTP server among those availalble or if the NTP
client is synchronizing again after a synchronization loss..
autoNTPSerDetect
The NTP client has just detected a new NTP server that it can use to
send its requests and retrieve the time. This Trap is only sent if the NTP
mode is in automatic, at the start of the product.
noNTPSerDetected
The NTP client could not synchronize because it received no response
to retrieve the time information.
trackingNTPSer
The NTP client is synchronized on the NTP server selected. It generally
fol-lows the alarm neNTPSerSerlected to inform that the synchronization
is done.
lostNTPSync
The NTP client has lost the synchronization. It usually happens if there
is a network issue or if the time servers are all unreacheable.
userLocked
The user forced the product to run in Stand-alone mode. The product is
not
sending
the
alarms
lostNTPSync,
trackingNTPSer,
newNTPSerSelected and ntpStarting anymore as the NTP client is
disable in this mode..
►
SNMP write services:
If 'ON' is checked, the SNMP write service is enabled.
If 'OFF' is checked, the SNMP write service is disabled.
►
The MIB (Management Information Base) file of the product can be downloaded by visiting our
website
https://www.gorgy-timing.fr/188-modes-d-emploi.htm
It can be read with a text editor or by
an SNMP client.
B. SNMP configuration by software
The functionalities accessible through the web page are also configurable through SNMP. Moreover,
some options are only available through SNMP and are not proposed by the web page (for example,
some advanced actions on the stopwatch).
Here are the OIDs available on the LEDI®. A description is provided in the table next to the name of the
field and the OID, as well as a status on the use in retrieval or configuration. If the "GET" or "SET"
column contains "Y", then the field is accessible by the method concerned. Otherwise, the column
contains "N".
The OIDs all start with 1.3.6.1.4.1.8955.1.16 and end with the numbers shown in the following
table
Summary of Contents for LEDI
Page 10: ...10 MDE LEDI 1099V4 0 Outdoor clock wall mount...
Page 11: ...MDE LEDI 1099V4 0 11 ENGLISH LEDI POOL Wall mount LEDI WORLD Wall mount...
Page 16: ...16 MDE LEDI 1099V4 0 1 3 5 Ceiling Mounting with bracket for LEDI outdoor clock single face...
Page 18: ...18 MDE LEDI 1099V4 0 1 3 7 Ceiling Mounting with bracket for LEDI outdoor clock double face...
Page 20: ...20 MDE LEDI 1099V4 0 1 3 9 Ceiling Mounting with bracket for LEDI World...
Page 26: ...26 MDE LEDI 1099V4 0...
Page 34: ...34 MDE LEDI 1099V4 0 4 1 1 Configuration date heure...
Page 36: ...36 MDE LEDI 1099V4 0 4 2 LEDICA CLOCK 4 2 1 Settings hour minute 4 2 2 Advanced settings...
Page 37: ...MDE LEDI 1099V4 0 37 ENGLISH 4 2 3 Setting the calendar...