398309
Single-phase connection with total power limiter
(only in
model with four cooking zones)
• If your home main fuse does not allow 32-ampere
current, then the function of total power limiter can be
activated on the hob so that the current never exceeds 16
A.
• If you activate the total power limiter, then the power
of each cooking zone may only be increased until total
power reaches the limit. When the limit is reached, the
hob will beep and the setting display will fl ash.
• The setting can be activated within two minutes after
connecting the hob to the power mains (the appliance
must be switched off and unlocked).
• Simultaneously press all keys (sensors) for selecting the
cooking zones and hold them for 3 seconds until you
hear a short beep. »Hi« will appear on the display. This
stands for »High« power.
• Press the »–« or »+« sensor to change the setting to »Lo«.
This stands for »Low« power.
• To confi rm the setting, touch all keys for selecting the
cooking zones again and hold them for 3 seconds. A
short acoustic signal will be emitted and the display will
go blank..
• The low power setting is now stored. if you wish to
change this setting again, the appliance must be
disconnected from the power mains for a few seconds.
Note:
The setting procedure may be interrupted by
pressing the on/off key (A); alternatively, the process is
cancelled automatically after one minute. The previous
setting will remain active.
Example:
If two cooking zones are set to »P« level, the
other two cooking zones cannot be used. If you wish to use
all four cooking zones simultaneously, each zone can be set
to a maximum level of 7.