SERVICE
DIRTY
INSUFFICIENT AIR
FLOW THROUGH
THE FIREBOX
Is the air supply
clogged?
Is FAN 1 Working?
Are the silicon
tubes connected
properly?
Is the flow meter
working?
•
Check the voltage on the output on
the electronics
•
Check the presostat
•
Replace the fan
YES
•
Replace them if the are damaged or
broken
•
If they are clogged of pressed, clean
them and position them correctly
•
Replace the electronics
•
Check the air supply in the room
•
Check the air supply to the boiler
•
Check if the burning pot and the
space beneath are clean
•
Check the sealing on the doors
•
Check the sealing on the fuel
reservoir door
YES
NO
YES
NO
YES
NO
NO