13 ALARM
STATUSES
SERVICE
ALARM FIRE
UNSUCCESSFULL
IGNITION
Are there pellets in
the container?
Is STB protection
active?
Is the burning pot
clean?
Does the plug work?
Deactivate the
protection by
pressing the
button
NO
•
Check the presostat
•
Check the sealing
•
Check the air supply to
the boiler room
•
Check the chimney draft
•
Clean the burning pot
and the fireplace
•
Replace the plug
•
Check the output on the
electronics with voltmeter
•
Check the safety relay
Fill the
container
with pellets
YES
YES
NO
NO
YES
NO